SERVICE (CONT.)
Temperature Sensor (all Models)
FIG. 68 TEMPERATURE SENSOR
FIG. 67 TEMPERATURE SENSOR
Location:
The Temperature Sensor is located inside the cabinet 
between the fan and the water coil.
Test Procedures:
1.  Remove the left side housing panel.
2.  Connect a voltmeter across the two leads of the 
temperature sensor (leave plug connected);
 
The indication must be:
 
a) Approx. 1.4 vdc @ 71° F
 
b) Approx. 2.6 vdc @ 32° F
If voltage reading is 0v, the Control Board is not sup-
plying the necessary 5v and should be replaced. If the 
reading stays at 5vdc, replace sensor.
Alternate Test:
2.  Disconnect the plug on sensor leads and check 
resistance as indicated in chart.
If resistance reading is not within the range listed in 
chart, replace sensor.
Removal and Replacement:
1.  Remove the left side housing panel.
2.  Disconnect the plug on the temperature sensor 
leads from the connector on the dispenser main 
harness.
3.  Open the cabinet door and remove the product 
containers.
4.  Remove the cabinet fan and fan guard assembly.
5.  Clip off the connector and pull the temperature 
sensor from the top left rear of the cabinet and 
discard.
6.  Push new temperature sensor wires into the grom-
met at the top left rear of the cabinet and secure to 
sensor mounting clip.
7.  Refer to Fig. 68 and connect the wires to the new 
plug.
8.  Connect the sensor plug to the connector from the 
main harness.
9.  Reinstall the cabinet fan and guard assembly.
10. Reinstall the left side housing panel.
1.  BLK to GRY J7-1
  (Control Board) Positive
2.  BLK to WHI/BLK J7-2
  (Control Board) Negative
2        1
 TEMP 
RESISTANCE 
VOLTAGE
 
  SHORTED 
0 Ω 
0VDC
 
32° F 
1.5k Ω 
2.5VDC
 
   0° C
 
77° F 
350 Ω 
1.1VDC
  25.0° C
 
OPEN 
INFINITE 
5.0VDC
NOTE: ALL FIGURES LISTED ABOVE ARE APPROXIMATE.
49179  020514