SERVICE (cont.)
Electronic Controls (cont.)
Liquid Level Control Test Procedure
1.  Disconnect the dispenser from the power source.
2.  Check the voltage across terminals 3 & 4 of the 
electronic  control  assembly  with  a  voltmeter. 
Connect the dispenser to the power source. The 
indication must be 200 to 240 volts ac for 200 to 
240 volt models.
3.  Disconnect the dispenser from the power source. If 
voltage was present as described, proceed to #4. If 
voltage was not present as described, refer to the 
Wiring Diagrams and check the dispenser wiring 
harness.
4.  Remove the pink wire from terminal 5 of the elec-
tronic control assembly.
5.  Check the voltage across terminals 1 & 4 of the elec-
tronic control assembly with a voltmeter. Connect 
the dispenser to the power source. The indication 
must be 200 to 240 volts ac for 200 to 240 volt 
models after a delay of approximately 5 seconds.
6.  Disconnect the dispenser from the power source.
If voltage was present as described, the liquid level 
control of the system is operating properly, proceed 
to #7.
If voltage was not present as described, replace the 
electronic control assembly and the temperature sen-
sor in the tank lid.
NOTE - Each electronic control assembly is calibrated 
to a temperature sensor. Both components MUST be 
replaced as a set.
7.  Reconnect the pink wire to terminal 5 of the elec-
tronic control assembly.
8.  Loosen the compression fitting, remove the probe 
from the tank lid, and inspect it for mineral depos-
its. Replace it if necessary. Keep the exposed ends 
of the probe away from any metal surface of the 
dispenser.
9.  Check the voltage across the terminals 1 & 4 of 
the electronic control assembly with a voltmeter. 
Connect the dispenser to the power source.  The 
indication must be 200 to 240 volts ac for 200 to 
240 volt models after a delay of approximately 5 
seconds.
10. Touch the screw head end of the probe to the dis-
penser housing. The indication must be 0.
11.  
Move  the  probe  away  from  the  dispenser 
housing. The indication must again be 200 to 240 
volts ac for 200 to 240 volt models after a delay of 
approximately 5 seconds.
12. Disconnect the dispenser from the power source.
If  voltage  was  present  as  described,  reinstall  the 
probe, the sensing function of the system is operating 
properly. 
If voltage was not present as described, check the pink 
probe wire and the green ground wire for continuity 
and/or replace the probe.
Temperature control Flow Charts
10889 091599