SERVICE (cont.)
Tank Heater
Location:
The tank heater is located in the tank lid.
P1993
FIG. 11 TANK HEATER
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Check the voltage across the terminals of the tank 
heater with a voltmeter. Connect the dispenser to 
the power source. The indication must be 200 to 
240 volts ac for 200 to 240 volt models.
3.  Disconnect the dispenser from the power source.
If continuity is present as described, reinstall the tank 
heater. The tank heater is operating properly.
If continuity is not present as described, replace the 
tank heater.
Removal and Replacement:
1.  Remove the wires to the tank heater.
2.  Remove  the  8-32  nuts  from  the  tank  heater 
flange.
3.  Remove the tank heater.
4.  Inspect the tank heater gasket and replace if neces-
sary.
5.  Securely install the new tank heater. Be certain of 
a watertight seal.
6.  Reconnect the wires, FIG. 12.
BLU to Triac Assy
BLK to Limit Thermostat
P1780
FIG. 12 TANK HEATER WIRING
If voltage is present as described, proceed to #4.
If voltage is not present as described, replace the tank 
heater.
4.  Remove the tank heater from the tank lid and in-
spect it for cracks in the sheath.
10889 091599