Bunn JDF-4SB Manual De Usuario

Descargar
Página de 57
49
SERVICE (CONT.)
Transformer - Lited Doors (JDF-2S, JDF-4S)
Removal and Replacement:
1.  Loosen the two #8-32 screws securing the com-
ponent bracket to the dispenser housing base.
2.  Pull component bracket out the front of the dispenser 
far enough so the transformer connector can be 
disconnected from the main wiring harness.
3  Disconnect the transformer four pin connector from 
the four pin plug on the main wiring harness.
4.  Remove the two #6-32 keps nuts securing the 
transformer to the component bracket.
5.  Remove and discard the transformer.
6.  Install new transformer on the component bracket 
and secure with two #6-32 keps nuts.
7.  Connect the four pin connector on the transformer 
to four pin plug on the main wiring harness.
8.  Place the component bracket into position and 
tighten the two #8-32 screws.
WHI/BLK - T12
WHI/GRN - T8
WHI - 120V T2, 240V T6
BLK - TI
FIG. 72  TRANSFORMER TERMINALS
P1647
FIG. 71 TRANSFORMER
Location:
  The transformer is located on the electrical com-
ponent mounting bracket on the lower front of the 
dispenser behind the splash panel.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the four pin plug from the main harness 
from the four pin connector on the transformer.
3  Check the voltage across black wire pin 1 and the 
white wire pin 2 on the plug from the main har-
ness. Connect the dispenser to power source. The 
indication must be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt and three wire 120/240 volt 
models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described reconnect the plug 
and the connector and proceed to #5.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the main wiring harness.
5.  Check the voltage between J3-5 and J3-6 on the 
six pin connector at the control board. Connect the 
dispenser to the power source. The indication must 
be 24 volts ac.
If voltage is present as described the transformer is 
operating properly.
If voltage is not present as described, replace the 
transformer.
P3864
+
A
C
A
C
49179  110613