BYPASS OZ/M (SINGLE BREWERS)
 
This function allows the operator to view or to enter 
the actual flow rate coming out of the bypass nozzle.  
This is NOT used to change the actual flow rate, but to 
tell the internal controller how fast the water is flowing. 
The unit of measure is ounces per minute. 
Procedure to adjust the flow rate setting:
1.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads  
BYPAS OZ/M. The number represents what the 
brewer thinks is the flow rate of the bypass valve 
in ounces per minute.
2.  If the actual flow rate of the bypass valve is known, 
but is different than the number on the display, 
use the (-) and (+) to enter the correct flow rate 
in ounces per minute.
3.  When finished, press and release DONE. This saves 
the new setting and advances to the next function 
screen, CALIBRATE FLOW. Another alternative is to 
press the ON/OFF switch located on the front switch 
panel to exit the BYPASS OZ/M function and return to 
the MAIN SCREEN. 
BYPASS OZ/M (DUAL BREWERS)
 
This function allows the operator to view or to enter 
the actual flow rate coming out of the bypass nozzle.  
This is NOT used to change the actual flow rate, but to 
tell the internal controller how fast the water is flowing. 
The unit of measure is ounces per minute. 
Procedure to adjust the flow rate setting:
1.  Press and hold upper right hidden switch until 
display reads UNITS. Release switch. Continue 
to press and release switch until display reads 
BYPASS OZ/M. The number represents what the 
brewer thinks is the flow rate of the bypass valve 
in ounces per minute.
2.  If the actual flow rate of the bypass valve is known, 
but is different than the number on the display, 
use the (-) and (+) to enter the correct flow rate 
in ounces per minute.
3.  When finished,  press and release the DONE.   This 
saves the new setting and advances to R BYPS 
OZ/M. When finished setting right side, press and 
release DONE to advance to next function screen, 
CALIBRATE FLOW. Another alternative is to press 
and release either ON/OFF switch located on the 
front switch panel to exit the BYPASS OZ/M func-
tion and return to the MAIN SCREEN.
R BYPS  OZ/M:  XX.X
(-)      DONE      (+)
L BYPS  OZ/M:  XX.X
(-)      DONE      (+)
CALIBRATE FLOW?
NO                   YES
BYPS  OZ/M:  XX.X
(-)      DONE      (+)
CALIBRATE FLOW?
NO                   YES
PROGRAMMING FUNCTIONS - (cont.)
41343 080108