BREW LOCKOUT (YES/NO)
Setting to "YES" only allows brewing at or above the "SET READY" temp screen.
BREW  LOCKOUT ?
NO          DONE       YES
   BREW  OZ   A:    8.0
(-)         DONE        (+)
BREW METER  A:   2
  -                                +
BREW OZ. (LARGE) (1-16)
Adjust brew volume for "LARGE" button.
BREW METER (LARGE) (1-5)
Simplified pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,
2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.
BREW OZ. (SMALL) (1-16)
Adjust brew volume for "SMALL" button.
BREW METER (SMALL) (1-5)
Simplified pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,
2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.
   BREW  OZ   B:    6.0
(-)         DONE        (+)
BREW METER  B:   1
ENTER SERVICE #
NO          DONE       YES
ENTER SERVICE #
Program service phone number to be displayed anytime there is a fault message.
ENTER PASSWORD
User must enter a 3 digit number to access remainder of adjustments. If no 
number has been pre programmed (0 0 0), then access is allowed.
SET PASSWORD
0           0           0
ENTER PASSWORD
0           0           0
  SET  TEMP:        200°
(-)         DONE        (+)
SET  LANGUAGE ?
NO                          YES
UNITS
METRIC  DONE   ENG
SET PASSWORD (001-999)
Program any three digit number as a password. 
LEVEL 2
SET LANGUAGE
 
Choose between English or Spanish.
UNITS 
Choose between English or metric.
SET TEMP
Adjust tank temperature 185 to 205° F (85 to 96° C)
PROGRAM FUNCTIONS
SET READY
Sets the minimum temperature allowable to start a brew cycle. Range: (2° to 
20° F) or (2° to 10° C) below the set temperature.
 SET  READY:     195°
(-)         DONE        (+)
HOT H2o LOCKOUT
Setting to "YES" will only allow dispensing of hot water at or above the "H2o 
READY" temp screen.
   HOT H2O LOCKOUT  ?
NO          DONE       YES
CONTINUED
41170.1 050312
  -                                +