SERVICE
 
This section provides procedures for testing and 
replacing  various  major  components  used  in  this 
brewer should service become necessary.  Refer to 
Troubleshooting  for  assistance  in  determining  the 
cause of any problem.
WARNING - Inspection, testing, and repair of electri-
cal equipment should be performed only by qualified 
service personnel.  The brewer should be unplugged 
when servicing, except when electrical tests are re-
quired and the test procedure specifically states to 
plug-in the brewer.
COMPONENT ACCESS
WARNING
 - Disconnect the brewer from the power 
source before the removal of any panel or the replace-
ment of any component.
 
All components are accessible by the removal of 
the top cover, front inspection panel, and rear panel. 
CONTROL THERMOSTAT
FIG. 10-1 COMPONENT ACCESS
FIG. 10-2 CONTROL THERMOSTAT
Location:
 
 The control thermostat is located in the hood.
Test Procedures:
1.   Disconnect the brewer from the power source.
2.   Locate the blue wire on the control thermostat.
3.   Check the voltage across the blue/black wire on 
the control thermostat  and the white wire on the 
tank heater  on  120V models or red wire on the 
tank  heater  on  two  wire  200V  or  230V  models 
with a voltmeter. Connect the brewer to the power 
source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models.
 
b) 200  to 230 volts ac for two wire 200 or 230 
volt models.
4.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wiring 
diagrams and check the brewer wiring harness.
5.  Locate the black wire on the control thermostat.
6.  Gently remove the capillary bulb and grommet 
 
from the tank.
7.  Check  the  voltage  across  the  black  wire  of  the 
control thermostat and the white wire on the tank 
heater  on  120V models or red wire on the tank 
heater on two wire 200V or 230V models with a 
voltmeter when the control thermostat is turned 
fully clockwise. Connect the brewer to the power 
41722 070209