Char-Broil 7101366 Manual De Usuario

Descargar
Página de 20
• NEVER store a spare LP cylinder under or near the 
appliance or in an enclosed area.
• Never fill a cylinder beyond 80% full.
• An over filled or improperly stored cylinder is a hazard 
due to possible gas release from the safety relief valve.  
This could cause an intense fire with risk of property 
damage, serious injury or death.
• If you see, smell or hear gas escaping, immediately get 
away from the LP cylinder/appliance and call your fire 
department.
• Keep LP tank at a minimum distance of 24” (inches) away 
from appliance at all times.
DANGER
USE AND CARE
• A disconnected LP cylinder in
storage or being transported
must have a safety cap installed (as shown).
Do not store an LP cylinder in enclosed spaces
such as a carport, garage, porch, covered
patio or other building. Never leave an LP cylinder
inside a vehicle which may become overheated
by the sun.
• Do not store an LP cylinder in an area where children play.
LP Cylinder   
• The LP cylinder used with your appliance must meet the 
following requirements:
• Use LP cylinders only with these required measurements: 12" 
(30.5cm) (diameter) x 18" (45.7 cm) (tall) with 20 lb. (9 kg.) 
capacity maximum.
• LP cylinders must be constructed and marked in accordance 
with specifications for LP cylinders of the U.S. Department of 
Transportation (DOT) or the National Standard of Canada, 
CAN/CSA-339, Cylinders, Spheres and Tubes for 
Transportation of Dangerous Goods; and commission, as 
applicable. See LP cylinder collar for marking.
• LP cylinder valve must have:
• Type 1 outlet compatible with 
regulator or Oil-Less Turkey Fryer.
• Safety relief valve.
• UL listed Overfill Protection 
Device (OPD). This OPD safety
feature is identified by a unique triangular hand wheel. 
Use 
only LP cylinders equipped with this type of valve.
• LP cylinder must be arranged for vapor withdrawal and include 
collar to protect LP cylinder valve. Always keep LP cylinders in 
upright position during use, transit or storage.
OPD Hand Wheel
LP (Liquefied Petroleum Gas)
• LP gas is nontoxic, odorless and colorless when produced. For 
Your Safety, LP gas has been given an odor (similar to rotten 
cabbage) so that it can be smelled. 
• LP gas is highly flammable and may ignite unexpectedly when 
mixed with air.
LP Cylinder Filling
• Use only licensed and experienced dealers.
• LP dealer must purge new cylinder before filling.
• Dealer should NEVER fill LP cylinder more than 80% of LP 
cylinder volume. Volume of propane in cylinder will vary by 
temperature.
• A frosty regulator indicates gas overfill. Immediately close LP 
cylinder valve and call local LP gas dealer for assistance.
• Do not release liquid propane (LP) gas into the atmosphere. 
This is a hazardous practice.
• To remove gas from LP cylinder, contact an LP dealer or call a 
local fire department for assistance. Check the telephone 
directory under “Gas Companies” for nearest certified LP 
dealers.
4  •  07101366
LP Cylinder Valve
Retainer Strap
Safety
Cap
LP Cylinder Removal, Transport and Storage
• Turn OFF control knob and LP cylinder valve. Turn coupling nut 
counterclockwise by hand only - do not use tools to 
disconnect. Install safety cap onto LP cylinder valve. Always 
use cap and strap supplied with valve. 
Failure to use safety 
cap as directed may result in serious personal injury 
and/or property damage. 
24”