Condenser Cleaning
Interval - Every Three Months
To maintain operational efficiency, keep the front grille 
free of dust and lint, and clean the condenser every three 
months. Depending on environmental conditions, more 
or less frequent cleaning may be necessary.
WARNING
Disconnect electric power to the unit before 
cleaning the condenser.
WARNING
DO NOT touch the condenser fins. The condenser 
fins are SHARP and can be easily damaged.
IMPORTANT
IMPORTANT
DO NOT use any type of cleaner on the condenser 
unit.
1. Disconnect power to the unit.
Figure 5
2. Remove the control knob (Figure 5, 1) by pulling it 
straight out, away from grille.
3. Remove screw from grille (Figure 5, 2) and save.
4. Remove the grille.
Figure 6
5. Clean the condenser coil (Figure 6, 1) using a using a 
soft brush with a “combing” action or vacuum cleaner. 
Do not touch the condenser coil.
Figure 7
6. Place the two hook-hinges (Figure 7, 1) located on the 
rear bottom side of the grille onto the front lip of the 
unit base. Swing the grille up into position, and align 
the screw hole on the grille to the grille screw hole on 
the cabinet.
7. Insert the screw (Figure 5, 2). Do not overtighten.
8. Reinstall the control knob (Figure 5, 1).
9. Reconnect power to the unit.
Leveling
It is important that units equipped with adjustable feet 
are level, for proper door and ice maker (if equipped) 
operation. 
To level units with adjustable feet:
Figure 8
1. Use a level to check the levelness of the unit from 
front to back and from side to side. Level should be 
placed along top edge and side edge as shown 
(Figure 8).
Figure 9