F. Water Supply and Drain Connections
 WARNING
Water supply and drain connections must be installed in accordance with applicable 
national, state, and local regulations.
NOTICE
• Normal operating water temperature must be within 45°F to 90°F (7°C to 
32°C). Operation of the appliance, for extended periods, outside of this normal 
temperature range may affect appliance performance.
• Water supply pressure must be a minimum of 7 PSIG and a maximum of 
113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve 
is required.
• External filters, strainers, or softeners may be required depending on water quality. 
Contact your local Hoshizaki Certified Service Representative or local Hoshizaki 
distributor for recommendations.
• Connect to potable water supply only. Do not connect to a hot-water supply.
• In areas where water damage is a concern, install in a contained area with a floor 
drain. 
• Water line installation to the appliance is not warranted by Hoshizaki.
• Water-hammer issues must be resolved by a qualified plumber before installing 
the appliance. Water hammer can cause appliance damage that may lead to 
water leakage or flooding.
• A minimum of 1/2" nominal ID hard pipe or equivalent is required for the drain 
line. Installing a smaller diameter drain line will reduce water flow and may lead to 
water leakage or flooding.
• If using the optional drain pump (HS-5061), test its operation every time the 
appliance is cleaned and sanitized. See "IV.E. Optional Drain Pump HS-5061" for 
details. If the optional drain pump is not operating properly, water could back up 
and overflow, leading to costly water damage.
Water Supply 
Inlet
Minimum Water Supply 
Line Size
Drain Outlet
Minimum Drain 
Line Size
1/2" Female Pipe 
Thread (FPT)
1/4" Nominal ID 
Copper Water Tubing or 
Equivalent
1/2" Female Pipe 
Thread (FPT)
1/2" Nominal 
ID Hard Pipe or 
Equivalent
• A plumbing permit and services of a licensed plumber may be required in some areas.
• A water supply line shut-off valve and drain valve must be installed. 
• Be sure there is sufficient extra water supply line and drain line for the appliance to be 
pulled out for service.
• Drain line should not be piped directly to the sewer system. An air gap of a minimum of 
2 vertical inches (5 cm) must be between the end of the drain pipe from the appliance 
and the floor drain.