Carrier 50KQL-1PD Manual De Usuario

Descargar
Página de 36
2
Quiet operation
The Carrier Console WSHP provides 
exceptionally quiet operation for maxi-
mum comfort.
Design flexibility
Aquazone™ Console WSHP units are 
offered in 5 capacity sizes and 3 differ-
ent voltages to meet individual zone 
needs efficiently and effectively. 
Standard and extended operating 
range units are available to suit a 
variety of application requirements.
Safe, reliable operation
Standard safety features include: high 
and low pressure monitoring and field 
selectable water and air coil freeze pro-
tection sensing. All safety controls may 
be reset at the thermostat. Each unit is 
tested and run at the factory to ensure 
proper operation of all components 
and safety switches.
All components are carefully 
designed and selected for endurance, 
durability, and carefree day-to-day 
operation.
The water-to-refrigerant heat 
exchanger has copper inner and steel 
outer tubing which is painted on the 
outside to provide corrosion resistance 
protection. Cupronickel heat exchang-
ers are available and should be used on 
all open loop applications.
Units are rated and certified in 
accordance with ARI/ISO/ASHRAE 
13256-1 performance standard, and 
are CSA/NRTL listed.
Installation ease
The unit is packaged for simple, low 
cost handling, with minimal time re-
quired for installation. The console unit 
arrives at the jobsite fully assembled to 
minimize installation time and reduce 
installation cost. All units are pre-wired 
and factory charged with R-22 
refrigerant.
Water connections are available in a 
variety of configurations direct from 
the factory. The standard configuration 
is 
5
/
8
 in. OD Sweat connections for 
maximum flexibility in the field. Both 
FPT and MPT are available as factory- 
installed options to improve installation 
efficiency. Additionally, factory-
installed motorized water shutoff 
valves are available for use on energy 
conserving systems employing a 
variable pumping technique.
The standard electrical connections 
are made quickly and directly to a pow-
er distribution terminal block. To fur-
ther improve installation efficiency, a 
fused or unfused disconnect switch as 
well as a 20 amp plug and cord are 
available as factory-installed options.
5
/
8
 in. ID vinyl condensate con-
nection is provided for connection to 
the field-installed condensate line.
Compact cabinet design dimen-
sions are 12 in. deep, 48 in. wide and 
24 in. tall (with 3 in. subbase). For flex-
ibility, the controls can be mounted on 
the top right or left side. Additionally, 
the sloped top design discourages the 
use of the unit as a shelf or coffee hold-
er, preventing air blockage and any 
spills from damaging the unit.
No-fuss maintenance and 
serviceability
Regular maintenance or service to the 
console WSHP units require little time. 
Large service access panels enable 
quick inspection for problem solving 
and the control box swings down for 
easy access to the controls.
Fan motor sleeve bearings are 
permanently lubricated for worry-free 
performance. If the unit does require 
service, an easily removable cabinet 
and slide out fan section make access 
simple.
Refrigerant circuit protection is de-
signed to result in fewer service calls. 
Units are equipped with easily accessi-
ble service access ports on both the 
suction and the discharge refrigerant 
lines for on-site testing and environ-
mentally correct refrigerant recovery. 
Filter racks provide easy filter access 
for cleaning.
Maximum control flexibility
Aquazone water source heat pumps 
provide reliable control operation using 
a standard microprocessor board.
Flexible alternatives for many direct 
digital control (DDC) applications in-
clude the Carrier Comfort Network 
(CCN) and open protocol systems.
Carrier’s Aquazone standard unit 
solid-state control system, the Com-
plete C, provides control of the unit 
compressor, reversing valve, fan, safety 
features, and troubleshooting fault indi-
cation features. The Complete C is 
one of the most user friendly, low cost, 
and advanced control boards found in 
the WSHP industry. Many features are 
field selectable to provide the ultimate 
in field installation flexibility. The 
overall features of this standard control 
system include:
50 va transformer  Assists in 
accommodating accessory loads.
Table of contents
Page
Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ARI/ISO 13256-1 Capacity Ratings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-13
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14,15
Performance Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-21
Application Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22-24
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Typical Wiring Schematics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25-31
Typical Piping  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33-36
NRTL/C
As an E
NERGY
S
TAR
® Partner,
Carrier Corporation has deter-
mined that this product meets
the E
NERGY
S
TAR
guidelines
for energy efficiency.