SERVICE (cont.)
BREW/DILUTION TIMER (TB3 & TB6) 
Location:
 
The timer is located in left side of the hood.
Test Procedure:
NOTE: Do not remove or install wires while timer board 
is installed. Pressure applied to one side may cause 
damage to the board.
1.  Disconnect the brewer from the power source and 
remove the top cover.
2.  With a voltmeter, check the supply voltage across 
terminals TL1 and TL2. Connect the brewer to the 
power source. Turn on the "ON/OFF" switch. The 
voltage must be:
 
a)  120 volts ac for two wire 120 volt models.
 
b)  200 to 230 volts ac on two wire 200 volt or 
230 volt models.
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wir-
ing Diagrams and check the wiring harness.
4.  With a voltmeter, check the BREW output voltage 
across terminals TL2 and TL4; and the DILUTION 
output  voltage  across  terminals  TL2  and  TL6. 
Connect the brewer to the power source, turn on 
the "ON/OFF" switch and press the "START" switch. 
The voltage must be:
 
a) 120 volts ac for two wire 120 volt models.
 
b) 200 to 230 volts ac for two wire 200 volt or 230 
volt models.
FIG. 18-1 BREW/DILUTION TIMER
If voltage is present as described, the timer is operat-
ing properly. 
If voltage is not present as described, disconnect the 
brewer from the power source and replace the timer.
Removal and Replacement:
1.  Remove the two #6-32 screws, lock washers and 
spacers securing timer to bracket.
2.  Disconnect all wires from the timer.
3.  Refer to schematic and reconnect wires.
4.  Install new timer to bracket with the two #6-32 
screws, lock washers and spacers.
5.  Adjust the timer as required.
FIG. 18-2 TIMER TERMINALS
Terminals:
J-1  
½ batch connector
J-4  
Dilution delay time 1-2 (NORMAL), 3-4 (2x)
SW-1  Programming Enable/Disable
TRM-1 White/Violet   L1 in from ON/OFF switch
TRM-2 White (Red)  Neutral (L2)
TRM-3 White/Orange  Start switch
TRM-4 White/Green  Brew solenoid
TRM-5 White/Yellow  Start switch
TRM-6 White/Blue 
Dilution solenoids
J-4
J-1
SW1
TRM-6
TRM-5
TRM-4
TRM-3
TRM-2
TRM-1
41722 070209