Installation 
18
309572ZAG
Connect FTS and Heated Dual Whip Hose
1. Assemble JIC swivel fitting (5e) in female 
end of temp sensor (5a). Do not bend or 
kink probe. Torque connection to 14 ft-lbs 
(19 N•m). Do not over-torque. Assemble 
JIC swivel fitting (5d) into female end of B 
hose coupler (5b). Torque to a maximum of 
20 ft-lbs (27 N•m). Do not over-torque.
2. Carefully inset FTS probe into the A hose 
(1) section from the proportioner. Do not 
bend or kink probe. Connect to A side whip 
(6a). Torque fitting connections to 14 ft-lbs 
(19 N•m). Do not over-torque.
3. Connect the B hose coupler to the B hose 
section (2) and B side whip (6b). Torque fit-
ting connections to 20 ft-lbs (27 N•m). Do 
not over-torque.
4. Connect ground wire (K) of whip hose to 
the ground screw on the FTS (5a).  
5. Connect the electrical connectors (12).
6. Connect the FTS air line coupler (5c) 
between air hoses (3 and 8).
7. Connect the sensor cable of the hose (4) to 
the sensor cable of the FTS (5a). For 
non-RTD hoses, slide the insulator sleeves 
(S) over the connection. Leave slack in the 
cables to provide stress relief and to pre-
vent cable failure or errors.
page 21.
9. Cover the FTS and spacer with split foam 
(provided) and tape closed.
NOTICE
To prevent damage to probe, do not kink or 
excessively bend hose. Do not coil hose 
tighter than the minimum bend radius of 3 ft 
(0.9 m). Do not subject hose to excessive 
weight, impact, or other abuse.
See F
. 13 on page 19.
For 1/2 in. (13 mm) ID fluid hoses 
only:
 Prior to connecting the FTS, 
remove the adapters from the propor-
tioner fluid manifold and install them on 
the male ends of the hoses (1 and 2). 
Torque the A side hose to a maximum 
of 43 ft-lbs (58 N•m) and the B side 
hose to a maximum of 55 ft-lbs (74 
N•m). Continue on to step 1.
NOTICE
To avoid damage to FTS sensor cable, 
rotate FTS body so the cable lays between 
both fluid hoses to protect it from abrasive 
damage during use.
A grounding wire must be used to provide 
grounding.
Whip hose ground wire (K) must be 
connected to the ground screw on the 
FTS (5a) in order to drain static from the 
gun. If the FTS is not directly connected 
to the whip hose, a hose that includes a 
separate ground wire must be used 
between the FTS and whip hose. Con-
nect ground through a hose marked as 
not having the FTS cable selected from 
the “Standard 2 Component Hose” table 