Manitowoc Ice Q300 Manual De Usuario

Descargar
Página de 45
 
 
 
Section 2 
Component Disassembly 
2-1 
Disassembling the Dispenser Parts 
For Cleaning 
 
 
 
WARNING
 
Unplug unit before servicing or cleaning. 
The agitator is operated by a timer and can agitate at 
anytime. 
Electric Shock Hazard. 
 
Shut off water to ice machine. 
 
 
 
Locate a cylindrical object, such as a ballpoint 
pen with a cap on the pen. 
 
Insert the pen into the left and right black rubber 
holes in the top of the front panel of the 
dispenser. 
 
This action releases the two clips which hold the 
dispenser front panel in place. 
 
While applying pressure on the pen, pull the 
front panel forward slightly, so the clip in the 
panel does not snap back into place.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Hold the front panel of the dispenser on both 
sides and tilt the panel forward.  The front panel 
will be resting on the catch hooks at the bottom 
of the panel. 
QFA-291 ONLY - Disconnect water line at the 
front panel “quick disconnect” fitting.  
Black rubber 
holes 
Dispenser
Front  
Panel 
Catch 
Hook