Refer to the table below for troubleshooting information.  
 
Problem Cause 
Possible 
Solution 
Shelves Not Heating and 
Lights Not On 
Unit not plugged into power 
receptacle. 
Ensure unit power cord is 
connected to appropriate power 
receptacle. 
 
No Power to the unit. 
Check circuit breaker or fuses at 
building power panel. If problem 
persists, contact an authorized 
BKI service agent for corrective 
action. 
 
Power circuit breaker is OFF 
and Lights circuit breaker is 
OFF. 
Place the Power circuit breaker 
ON and the Lights circuit breaker 
ON. 
Power Circuit Breaker has 
Tripped 
Overload, short circuit or ground 
fault condition exists. 
Place circuit breaker actuator in 
the ON position. If circuit breaker 
trips again, contact an authorized 
BKI service agent for corrective 
action. 
No Heat to Single Shelf 
Power circuit breaker is OFF. 
Place the Power circuit breaker 
ON. 
 
Shelf Temperature control is 
turned fully counterclockwise. 
Adjust the shelf temperature 
control. Refer to the section 
entitled Temperature Adjustment 
on page 4. 
 
Defective Shelf. 
Contact an authorized BKI service 
agent for corrective action. 
 
Loose Wire or bad Connection. 
Contact an authorized BKI service 
agent for corrective action. 
 
Shelf Temperature control is 
defective. 
Contact an authorized BKI service 
agent for corrective action. 
Individual Light is not On 
Failed fluorescent lamp. 
Change fluorescent lamp. 
 
Possible Ballast failure. 
Contact an authorized BKI service 
agent for corrective action. 
Holding Temperature Not 
Adequate
 
Unit has not been preheated. 
Refer to the preheating section on 
page 4. If problem persists, 
contact an authorized BKI service 
agent for corrective action. 
 
Product is below 160
° F when 
loaded. 
Check product temperature 
before loading the unit. 
 
Loose Wire or bad Connection. 
Contact an authorized BKI service 
agent for corrective action. 
 
Shelf temperature control not 
set properly. 
Adjust the shelf temperature 
control. Refer to the section 
entitled Temperature Adjustment 
on page 4. 
Switch Plate Pilot Light is 
On 
Overtemperature condition 
exists. Possible fan failure. 
Turn unit OFF then contact an 
authorized BKI service agent for 
corrective action.