NuTone 768CHNT Manual De Usuario

Descargar
Página de 12
Page 3
MODEL  768CHNT 
FINIAL
NUT
GLASS
SHADE
GRILLE
PAN
ROD
WASHER
60 WATT
MAX.
B10 BASE
CANDELABRA
BULBS
(2 REQ.)
STEEL
WASHER
FELT
WASHER
(Add second
washer as
needed to
secure shade
tightly.)
FELT
WASHER
B L K
V E N T
S W I T C H
B L U
B L K
W H T
W H T
W H T
L I G H T
( W H I T E )
G R D
V E N T
( B L A C K )
U N I T
S W I T C H  B O X
L I G H T
S W I T C H
L I N E
I N
B L K
R E D
W H T
G R D
SCHEMATIC WIRING DIAGRAM
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
WIRING
PLATE
120 VAC
LINE IN
BLUE
BLACK
RECEPTACLE
(FAN)
WHITE
RECEPTACLE
(LIGHT)
INSTALL THE HOUSING 
(continued)
ATTACH THE GRILLE PAN AND 
GLASS SHADE
INSTALL THE DUCTWORK
FLUSH
NOTE:  The  duct  connec-
tor  has  a  counter-balanced 
damper flap. The flap will be 
CONNECT THE WIRING
1.  Snap the damper/duct connector onto housing. Make sure 
that tabs on the connector lock into slots in housing. Top of 
damper/duct connector should be flush with top of housing.
2. Connect  4”  round  duct  to  damper/duct  connector  and 
extend duct to outside through a roof or wall cap. Check 
damper  to  make  sure  that  it  opens  freely. Tape  all  duct 
connections to make them secure and air tight.
“open” approx. 1” when duct connector is attached to housing. 
This design permits insulation to be in direct contact with fan/
light housing per UL (Underwriters Laboratories) standards. 
The slightest backdraft, however, will close the damper flap, 
preventing air from entering unit or finished space.
4. Place housing in opening so that its bottom edge is flush  
with finished ceiling. Nail to joist through keyhole on both 
sides. To ensure a noise-free installation, drive another nail 
through the top hole of each mounting bracket. 
Existing Construction
5. Additional  mounting  holes  are  provided  for  installations 
where access from above is inconvenient or not possible. 
Nail or screw housing directly to joists or framing.
ADDITIONAL
MOUNTING
HOLES
1.  Locate the grille pan over 
the fan housing and con-
nect  the  wiring  harness 
plug into white receptacle 
in the fan housing.
2. Insert rod through center 
hole  of  grille  pan.  Use 
washer  between  collar 
on rod and pan.
3. Thread  rod  onto  grille 
screw  in  housing,  until 
pan is tight against ceil-
ing.  Do  not  over-tighten 
mounting rod.
4. Install bulbs. Use 60-watt 
(maximum),  B10  type, 
candelabra bulbs. 
5. Place washers and glass 
shade over mounting rod 
and  align  shade  onto 
grille  pan.  Secure  glass 
shade  to  grille  pan  with 
felt  washer(s)  and  finial 
nut as shown.
6. Restore  electrical  power 
and  check  operation  of 
the unit.
1. Wire unit following diagram 
above. Run electrical cable as 
direct  as  possible  to  unit.  Do  not 
allow cable to touch sides or top of unit after installation is 
complete. 
GRILLE 
PAN
GRILLE
SCREW
WASHER
COLLAR
ROD
WASHER
GLASS SHADE