PROFESSIOnaL SERIES RanGETOPS  
36-InCH
model: PCG364GD
36-INCH RANGETOP AND CuTOuT DIMENSIONS
InSTaLLaTIOn OPTIOnS
To ensure professional results, the cabinet and 
countertop openings should be prepared by a 
qualified cabinet worker. The rangetop can be installed 
in various positions with the front either flush or 
projecting, depending on the countertop's depth.  
The rangetop is designed to hang from the countertop 
by its side flanges. The countertop however, must be 
strong enough to support the rangetop. It may be 
necessary to add a supporting cleat along each side or 
a 2 x 4 corner brace. Another alternative would be to 
construct a deck to set the rangetop on. Consult with 
the installation manual packed with the product for 
complete details before installing.
aBOVE a WaRmInG DRaWER
Thermador Professional Rangetops may be installed 
above a Thermador Warming Drawer to create a 
convenient cooking center. A minimum 2 
3
/
4
" clearance 
is required between the bottom of the rangetop and 
the top of the warming drawer. Refer to the warming 
drawer section for additional specifications.
BaCkGuaRD
A backguard must be utilized when there is less than 
a 12" horizontal clearance between combustible 
materials and the back edge of the rangetop. The 
Thermador Low Backguard must be ordered separately 
and installed at the rear of the rangetop. For island 
installations and other installations with more than 12" 
clearance, the provided stainless steel island trim will 
cover the backguard mounting flanges.
naTuRaL GaS OR LP
Thermador Professional Rangetops are shipped by 
the factory to operate on natural gas. They must be 
converted for use with propane. Verify the type of gas 
being used at the installation site matches the type 
of gas used by the appliance. If the location/job site 
requires conversion from natural gas to propane (LP), 
order PALPKITHC. Field conversion must be done by 
qualified service personnel only. Please refer to the  
LP Conversion Instructions packed with product for 
further information.
ImPORTanT
We strongly recommend that a Thermador  
Professional Wall or Island Hood or Custom Insert be 
installed with all Thermador Professional Rangetops. 
Downdraft ventilation should not be used. Do not 
install a microwave-hood combination above the 
rangetop, as these types of units do not provide 
the proper ventilation and are not suitable for use 
with Thermador Professional Rangetops.  Refer to 
the ventilation section or www.Thermador.com for a 
complete selection of Professional ventilation options, 
blowers, and accessories.
*specify 
 width
**min.30-40"
35
15
/
16
"
35
1
/
8
"
25
13
/
16
"
22
13
/
16
"
cooking
surface
8
1
/
16
"
3
/
8
"
1
1
/
4
"
***min.10"
***min.10"
2"x4"
corner support
  ** 40" minimum clearance 
 
from cooking surface to 
 
combustible surfaces.
***10" minimum clearance from cooking 
 
surface to combustible side wall.
measurement in inches
7
11
/
16
"
Note: Most hoods contain combustible
components that must be considered
when planning the installation.
*  Minimum hood 
  width recommended 
  equals that of the 
 rangetop.
PROFESSIOnaL SERIES RanGETOPS
ELECTRICaL anD GaS LOCaTIOnS
The gas and electrical supply must be located in an area that is accessible 
without requiring removal of the rangetop. The appliance electrical power 
cord and gas pipe connection are located on the left rear underside of  
the rangetop.
The junction box must be located within 3 feet (~900 mm) of the  
rangetop connection.
naTuRaL GaS REQuIREmEnTS:
Inlet Connection: 
1
/
2
" NPT  
(min. 
3
/
4
" dia. flex line) 
Supply Pressure: 6" min. to  
14" max. water column  
(14.9 mb to 34.9 mb)  
Manifold Pressure: 5" water  
column (12.5 mb)
PROPanE GaS REQuIREmEnTS:
Inlet Connection: 
1
/
2
" NPT  
(min. 
3
/
4
" dia. flex line) 
Supply Pressure: 11" min. to  
14" max. water column  
(27.4 mb to 34.9 mb)  
Manifold Pressure: 10" water 
column (24.9 mb)