Vermont Casting 3LDVT Manual De Usuario

Descargar
Página de 40
24
LDVT Series Direct Vent  Gas Fireplace
10007852
43LDVT
1.  Place rear log (BD15) on rear bracket 
(ensure log is centered and seated 
properly to the log support).
2.  Place front left log (BD16). Use log’s 
bottom notch to locate it onto the front 
support and just rest on top of the 
burner housing assembly.
3.  Place front right log (BD17). Use log’s 
bottom notch to locate it onto the front 
support and just rest on top of the 
burner housing assembly.
4.  Place ember material on top of burner.
5.  Scatter the ember material over the 
tiles on the front area of the burner 
housing. (Fig. 40) Do not pack the 
ember material. Separate it when 
unpacked and keep it in  a fluffy and 
loose condition for a more realistic 
ember effect.
6.  Place front center log (B138) on top of 
the two small shelves at the front log 
support, and between the left and right 
logs.
7.  Place top center log (BD18) on top of 
the rear log using the hole locator under the log and 
on top of front right log.
8.  Scatter lava rock material round the firebox base.
�����
����������
�����
Rear
(BD15)
Top Center
(BBD18)
Front Right
(BD17)
Front 
Left
(BD16)
Lava Rock
Front Center 
(B138)
Ember Material
Lava 
Rock
LG434
Fig. 40  Correct log placement for 43LDVT.
RN/RP & EN/EP Models
For units equipped with ‘HI/LO’ valves the flame 
adjustment is accomplished by rotating the ‘HI/LO’ 
adjustments knob located near the center of the gas 
control valve.  (Fig. 41-42)
It is important to periodically perform a visual check of 
the pilot and burner flames. Compare them to Figures 
43 and 44.
If the flame patterns appear abnormal contact a 
qualified service provider for service and adjustment.
Flame Characteristics
Flame & Temperature Adjustment
 
 
 
��
��
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Honeywell hi/lo knob
4/5/99   djt
Fig. 41  Flame adjustment knob for Honeywell valve.
LO
 
HI
 
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Turn 
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
Fig. 42  Flame adjustment knob for SIT valve.
������
����������������
����
SIT RN/RP
SIT EN/EP
FP1541
Fig. 43  Correct pilot flame appearance.
Do not place any of the lava rock material 
on the burner housing assembly.