DVBR Series Direct Vent Gas Fireplace
20000584
Cold climate installation recommendation:  
When installing this unit against a non-
insulated exterior wall or chase, it is 
mandatory that the outer walls be insulated 
to conform to applicable insulation codes.  
Hearth
A hearth is not mandatory but is recommended for  
aesthetic purposes.  We recommend a noncombustible 
hearth which projects out 12” (305 mm) or more from 
the front of the fireplace.
Framing and Finishing
Check fireplace to make sure it is levelled 
and properly positioned.
NOTE: If the optional Metro Face Kit (DVBR36 only) 
is to be installed, the fireplace may be placed on a 
4” (102 mm) raised platform. Raising the fireplace 
will give the best aestethic appearance but is not 
required.
To mount the appliance:
1.  Choose the location.
2.  Nailing flanges are supplied with the fireplace (found 
on the fireplace hearth). To level the box and secure 
it firmly in place, remove the nailing flanges from 
the hearth and install at the sides of the fireplace as 
shown in Figure 5.
FP549
nailing flange
1/05
Nail Top 
Standoffs
Nail Side-
nailing 
Flanges
FP549
Fig. 5  Nailing flanges.
Final Finishing
Noncombustible materials such as brick and tile can be 
extended over the black face of the unit (Do not cover 
the glass door.) If a Trim Kit is to be installed, brick and 
tile will have to be installed flush with the side of this 
appliance.
Gas Inlet & Manifold Pressures
   
Natural 
LP
  Minimum Inlet Pressure 
5.5” w.c. 
11.0” w.c.
  Maximum Inlet Pressure 
14.0” w.c.  14.0” w.c.
  Manifold Pressure 
3.5” w.c.  10.0” w.c.
Gas Specifications
 
 
 
 
Max. 
Min.
 
  
 
Gas 
 Input 
 Input
 
Model 
Fuel 
Control 
B.T.U.H 
B.T.U.H.
  DVBR36RN 
Natural Gas 
Millivolt Hi/Lo 
24,000 
16,000
  DVBR36RP 
Propane 
Millivolt Hi/Lo 
24,000 
17,500
  DVBR42RN 
Natural Gas   Millivolt  Hi/Lo  27,000 
18,000
  DVBR42RP 
Propane 
Millivolt  Hi/Lo  27,000 
19,700
DVBR36 / DVBR42
Certified to
ANSI Z21.88-2005 / CSA 2.33-2005
Vented Gas Fireplace Heater
Units: GFCN3J0, GFCN3M0
High Elevations
Input ratings are shown in BTU per hour and are 
certified without deration for elevations up to 
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, 
installations must be in accordance with the 
current ANSI Z223.1/NFPA 54 and/or local codes 
having jurisdiction.
In Canada, please consult provincial and/or local 
authorities having jurisdiction for installations at 
elevations above 4,500 feet (1,370m).
Gas Line Installation
When purging gas line the front glass must 
be removed.
The gas pipeline can be brought in through the right 
side of the appliance.  Knockouts are provided at con-
venient locations to allow for the gas pipe installation 
and testing of any gas connection.  
The gas line connection can be made with 3/8” copper 
tubing, 1/2” rigid pipe or an approved flex connector.  
Since some municipalities have  additional local codes, 
it is always best to consult your local authority and the 
CSA-B149.1 installation codes. For US installations 
consult the current National Fuel Gas Code, ANSI 
Z223.1/NFPA 54.