Replacing the Stylus
Replacing the Stylus
The AT-LP120-USB comes supplied with a high-quality Audio-Technica 
ATP-2 cartridge. The stylus should be replaced with a genuine  
Audio-Technica ATP-n2 stylus.
1.  Release the headshell assembly from the tone arm by turning the  
 
locking ring clockwise.
2.  Carefully remove the headshell assembly and turn it over so the  
 
stylus is visible.
3.  Remove the stylus assembly by pulling it away from the cartridge  
 
body at a slight angle. [See Figure 7.]
4.  Remove the replacement stylus from its package and carefully  
 
align it with the cartridge body.
5.  Gently push the stylus onto the cartridge body, being careful not to  
 
damage the stylus. The stylus assembly should click into place.
6.  Replace the headshell assembly on the tone arm and secure with  
 
the locking ring.
Figure 7 – Removing the Stylus
Mechanical Assembly 
1.  To replace the cartridge, first release the headshell assembly from  
 
the tone arm by turning the locking ring clockwise. Carefully  
 
remove the headshell assembly and turn it over so that the stylus  
 
is visible. Remove the stylus assembly by pulling it away from the  
 
cartridge body at a slight angle. [See Figure 7.] Place the stylus  
 
assembly out of harm’s way.
2.  Remove the cartridge body by loosening the two small screws  
 
securing the cartridge to the headshell. Set the hardware aside to  
 
be reused with the new cartridge.
3.  Unpack the new cartridge and carefully remove its stylus  
 
assembly. Place the stylus assembly out of harm’s way. Mount  
 
the new cartridge to the headshell assembly. Use the mounting  
 
hardware supplied with the new cartridge or the existing hardware  
 
removed at step 2. Tighten the mounting screws until just snug.  
 
Replace the stylus assembly briefly to check for mechanical  
 
interference with the mounting hardware. The stylus assembly  
 
should click into place. Make certain the new cartridge is properly  
 
positioned in the headcase assembly per the manufacturer’s  
 
instructions. Again remove the stylus assembly for safekeeping.
Electrical Connections
1.  Four terminals at the rear of the cartridge are color coded to match 
  
standard wiring in stereo tone arms. [See Figure 8.] Connect the  
 
cartridge with the slip-on lugs provided on the headshell wiring.  
 
neVeR SOLDeR TO CARTRIDGe TeRMInALS! Heat applied to  
 
the terminals will damage the internal cartridge wiring.
2.  For monaural operation, the left and right signal leads should be  
 
connected to the monaural output terminal and the left and right  
 
ground leads should be connected to the ground terminal. 
3.  Finally, gently push the stylus onto the cartridge body being  
 
careful not to damage the stylus. The stylus assembly should click  
 
into place. Replace the headshell assembly onto the tone arm  
 
taking care not to damage the stylus assembly.
(note: After replacing the cartridge, reset the tone arm balance, stylus 
force and anti-skate based on the new cartridge’s specifications.)
Figure 8 – Electrical Connections
Left Output 
(White)
Right Output 
(Red)
Right Ground 
(Green)
Left Ground 
(Blue)
Replacing the Cartridge