Description of Power Terminals
©
 2000–2003 Schneider Electric All Rights Reserved
20
09/2003
DESCRIPTION OF POWER TERMINALS
As shown in the drawing to the left, the ATV58 TRX power terminal 
arrangements differ from model to model. The locations of the power 
terminals are shown on pages 18–19. The following tables describe the 
characteristics of the power terminals and list maximum wire sizes and 
tightening torques for the various ATV58 TRX models.
 
CONDUIT CONNECTIONS FOR TYPE E AND TYPE F
DRIVE CONTROLLERS
The ATV58 TRX Type E and Type F drive controllers are furnished with four 
conduit openings at the bottom of the device. The conduit openings are 
closed with Type 1 rated plugs. The holes are intended for input and output 
power wiring, control wiring, and connection to external components such as 
DB resistors or line reactors. To maintain the enclosure rating, do not remove 
the plugs from unused conduit holes. Conduit holes are pre-drilled for the 
conduit listed in the table below.
Flexible conduit must be used up to the drive controller to facilitate removal 
of the terminal block cover. A minimum of 2 feet is recommended.
Function of Power Terminals
Terminal
Function
Found On
Ground terminal (2 provided on some models). All ATV58 TRX models.
L1
L2
Input power.
All models.
L3
All models except U09M2• and U18M2•
+
Connection for DB module.
Models U09M2• and U18M2•.
PA
PB
Connection for DB resistor.
All models except U09M2•, U18M2•, and 
C10N4–C33N4.
U
V
W
Output connections to motor.
All models.
K13
K14
N.O. auxiliary contact on controller’s output 
contactor. Maximum rating is 10 A at 600 Vac.
ATV58EU09M2ZU – U90N4FZ4.
Power Terminal Wire Size and Torque
Type FVC, Type H, and Type N Models
Maximum Wire Size
AWG (mm
2
)
Torque
lb-in (N•m)
U09M2, U18M2
14 (1.5)
5.0 (0.55)
U29M2, U41M2, U18N4, U29N4, U41N4
8 (6)
7.5 (0.85)
U54M2, U72M2, U54N4, U72N4, U90N4
8 (6)
7.5 (0.85)
U90M2, D12M2, D12N4, D16N4, D23N4
6 (10)
20 (2.25)
D16M2, D23M2, D28N4, D33N4, D46N4
2/0 (35)
88 (10)
D28M2, D33M2, D46M2, D54N4, D64N4, D79N4
4/0 (70)
170 (19)
C10N4X–C19N4X
500 MCM
375 (42)
C23N4X–C33N4X
Supply crimp style lugs to fit selected wire size.
Type E and Type F Models 
All models
10 (4)
5.0 (0.55)
75 °C copper.
Type E and Type F Models
Conduit Hole Size
Conduit Size
Hub Catalog No.
ATV58EU09M2ZU 
ATV58EU18M2ZU
7/8 inch
1/2 inch
25211-16102
All other ATV58 Type E and Type F 
Drive Controllers
1 and 3/32 inch
3/4 inch
25211-24102
L1 L2
+
U
V W
ATV58*U09M2 - U18M2
L1 L2 L3 PA PB U
V W
ATV58*U29M2 - D12M2
ATV58*U18N4 - D23N4
P
o
wrT
e
rm
sNe
w
.eps
J2B
J2A
ATV58EU09M2ZU and ATV58EU18M2ZU
(single-phase input only)
U
V
W K13 K14 +
 –
2
3
4
5
6
7
8
1
3
2
*
L2 L1
1
L3
* L3 is not used
J2B
J2A
ATV58Exxxxxxx
U
V
W K13 K14 PA  PB
2
3
4
5
6
7
8
1
3
2
4
L2 L1
1
L3
ATV58*D16M2 - D46M2
ATV58*U28N4 - D79N4
+
L1 L2 L3
PA PB U
V W
ATV58HC10N4X
PA
U
L1 L2 L3
V W
PA
(+)
PC
()
ATV58HC13N4X–C19N4X
U
V
W
L2 L3
L1
PA
(+)
PC
()
ATV58HC23N4X–C33N4X
U
V
W
L2 L3
L1
PA
(+)
PC
()
PA