Adjustment parameters can be viewed and modified when the access locking switch on the keypad 
display is not locked (see page 24). Adjustment parameters can be modified with the motor stopped or 
running.
Low Speed and High Speed
These frequency limits define the speed range permitted, as shown in the graph to the left. Low speed 
is adjustable from 0 to the High Speed setting and is factory set at 0 Hz. High Speed is adjustable from 
Low Speed to 500 Hz and is factory set to 50 or 60 Hz, depending on the configuration. The speed 
reference input is scaled between Low Speed and High Speed. It is possible to modify the scaling with 
the Low Speed Operation parameter.
Low Speed Operation
The Low Speed Operation parameter determines the two limits, High Speed (HSP) and Low Speed 
(LSP), that define the speed range permitted by the machine under actual operating conditions. This 
function can be used for all applications. The following table describes the three settings that can be 
assigned for this function.
Maximum Frequency
Maximum Frequency is used as a maximum speed clamp. The High Speed setting can not be above 
the Maximum Frequency setting. Maximum Frequency is adjustable from 40 to 500 Hz and factory set 
to 60 Hz or 72 Hz depending on the 50/60 Hz switch configuration.
Acceleration and Deceleration Ramp Times
The ramp times for acceleration and deceleration are determined by the requirements of the application 
and the dynamics of the machine. The following table shows the acceleration and deceleration settings.
Electronic Inversion of Output Phase
This parameter can be used to change the direction of motor rotation. This parameter is useful if it is 
determined, after the motor wiring has been connected, that the motor is not rotating in the correct 
direction.
Normal Mode
Pedestal Mode
Deadband Mode
LSP (Low Speed): From 0 to HSP, preset at 0. HSP (High Speed): from LSP to FMAX, preset at 50/60 Hz
x: configured from 0 to 20 mA, preset at 4 mA
y: configured from 4 to 20 mA, preset at 20 mA
Acceleration
Deceleration
Adjustment from 0.05 to 999.9 s, preset at 3 s.
Adjustment from 0.05 to 999.9 s, preset at 3 s.
0 V
0 mA
x mA
20 mA
10 V
20 mA
y mA
4 mA
High
Speed
Low
Speed
H
iLo
S
p
d.
e
p
s
f (Hz)
LSP
0 V
x mA
10 V
y mA
Ref.
HSP
OpSpd_Nml.eps
f (Hz)
LSP
0 V
x mA
10 V
y mA
Ref.
HSP
OpSpd_Pdstl.eps
f (Hz)
LSP
0 V
x mA
10 V
y mA
Ref.
HSP
OpSpd_Dbnd.eps
f (Hz)
t1
t
50/60
0
A
cc_Ram
p
.e
ps
t
f (Hz)
50/60
0
t1
D
ec_Ram
p
.e
ps
Low Speed and