Panasonic GN SERIES Manual De Usuario

Descargar
Página de 67
Product Description 
 
GN Series Hardware Manual 
26 
3.3.5  Reset Button 
To restart the GN unit e.g. after a system hang-up, press the reset button with a pen, for 
example. The system restarts automatically; you do not have to switch the computer off and 
on. 
 
NOTE
 
During a reset, all data in the main memory is erased. 
 
3.3.6  Status LEDs 
Status LED, storage medium (HDD/CF) 
LED 
Status 
Green 
CF activity. 
Red 
HDD activity. 
Status LED, system 
LED 
Status 
Green 
The system is running. 
Orange 
The system is in standby. 
Orange blinks 4 times 
Battery is improperly connected. Switch the +/- pole. 
Off 
The system is disconnected from the power source. 
 
 
NOTE
 
 
Use an isolating switch to turn the DC power supply on and off. 
 
The GN unit is only completely disconnected from the DC main power 
supply when the DC power cord is disconnected either from the power 
supply or the unit. Therefore, the DC power cord and its connectors must 
always remain easily accessible. 
 
3.3.7  Grounding Screw (M4) with Lock Washers 
The housing of the GN unit must be grounded by establishing a large-area contact between 
the grounding screw M4x19 (DIN7985) with 2 x lock washer M4 (DIN6797) and an appropriate 
grounding connection point. The minimum cross section of the grounding conductor is 1mm
2
 
(AWG 18). 
 
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net