Cornelius COR22RRTM Manual De Usuario

Descargar
Página de 22
 Reach-In Refrigerator Service Manual
© 2004, IMI Cornelius Inc.
- 17 -
Publication Number: 630460272SER
PROBLEM
POSSIBLE CAUSE
SOLUTION
NOISE
The refrigerator is not properly 
leveled.
Check if the noise goes away 
after you level the refrigerator.
The condenser is not fastened 
correctly. Copper tubings are in 
contact with metal.
While the compressor is 
working, check to see if metal 
parts are in contact with one 
another and/or if the screws 
that fasten the condenser are 
tightened.
The evaporator and/or 
condenser fans are loose.
Check if the fans are securely 
fastened. Also, check if the fan 
blades are loose, broken or 
crooked. If so, change the 
faulty blade.
Compressor has an internal 
noise.
If the noise persists after all 
other measures have been 
taken, it may be originating 
from the compressor.
EXTREME CONDENSATION 
INSIDE THE REFRIGERATOR
Thermostat knob is set at a 
very cold position.
Set the thermostat knob to a 
warmer position and check if 
the compressor stops 
according to the thermostat’s 
operating range.
The outside environment’s 
relative humidity is very high 
(over 75%).
This type of occurrence is 
caused by local climatic 
conditions and not by the 
refrigerated unit.
The refrigerator door won’t shut 
completely.
Check the door and/or the 
magnetic gasket. Adjust the 
door hinges if needed; replace 
the gasket if broken.
The refrigerator has been 
placed at an inadequate 
location.
The unit must not be near 
sources that produce too much 
heat.
NO ILLUMINATION
The light switch is in “off” 
position.
Press the light switch to the 
“on” position.
False contact on the light 
switch, the fluorescent tube, or 
the ballast.
Inspect all connections.
Light switch, ballast and/or 
fluorescent tube are damaged.
Replace the damaged 
component.