Toe-kick and venting grill
 Important
Poor ventilation leads to damage to the appliance.
Under no circumstances is it permitted to cover 
the air inlets and the exhaust air outlets of the 
appliance in the lower base area.
You must observe the minimum distance of 4" 
between the upper edge of the floor and the 
bottom edge of the door panel of the appliance. 
Pay attention to the height adjustment for the 
appliance by leveling the legs.
In relation to the standard height, the maximum height of the toe-
kick is 4". The toe-kick can be maximum ¾" thick.
Velcro adhesive strips are supplied on the front panel of the 
appliance to fasten the toe-kick to the appliance.
The venting grill and the exhaust air outlets of the appliance, as 
well as the access to the water filter (if available) are located above 
the toe-kick area. They must not be covered.
Door panel
Toe-kick
4"
(102)
For design reasons, it may be necessary to increase the distance 
between the upper edge of the floor and the bottom edge of the 
door panel of the appliance, so that it extends beyond the standard 
dimension of 4". The maximum dimension is 7 ⅛". The toe-kick 
thickness must not exceed ¾". If this is the case, ventilation grill, 
exhaust air outlets and the access to the water filter would become 
visible.
4"
(102)
7 ⅛"
(181)
2 ¹³⁄₁₆" - 4 ³⁄₁₆"
(72 - 106)
Upper molding
The planning of decorative upper molding above the cutout 
requires taking into account the actual or desired height of the 
door panel.
The overall height of the door panel will depend on:
 
– the height of the appliance, typically 84" (2134 mm)—lev-
eling legs allow height adjustment ranging from -½" (-13 
mm) to +1 
" (+35 mm)
 
– the installed height of the door panel (distance from the 
bottom edge of the door panel to the floor, typically 4" 
(102 mm), and, if desired, any extension of the custom 
panel above the appliance cutout)
 
– the appliance type (single door or bottom freezer)
Vertical section, side view
4"
(102)
⅛"
(3)
⅛"
(3)
   84"*
(2136)
79 ⅞"
(2029)
Possible extension of 
the door panel
Upper 
molding
Appliance
Appliance
door
Standard door panel
* Adjustment in leveling legs: -½" (-13 mm) to 1 ⅜" (35 mm)
 Important
Please recall that a panel should be installed at a 
minimum height of 4" (102 mm) from the floor to 
allow proper ventilation of the appliance.
Always ensure that the top of the cutout or upper decorative 
molding is at least 4" (102 mm) deep, so that the refrigerator 
can be properly secured to the cutout wall. This is particularly 
important if a protruding cutout is specially created and 
configured with a face frame. Furniture returns for any face frame 
must be a minimum of 4" (102 mm) deep.
Toe-kick area/upper molding of cutout (niche).
188
 Refrigeration
Numbers indicated  