Liebherr 20707 Manual De Usuario

Descargar
Página de 14
u
Screw in ball stud
 Fig. 3 (3)
 together with the soft stop
mechanism
 Fig. 3 (2)
 in the fastening hole.
u
Re-attach all covers
 Fig. 2 (5,6,7,8)
.
4 Kitchen Cabinet Construction
This is a fully integrated appliance which means that it is
fully  enclosed  by  a  kitchen  cabinet.  This  type  of  cabinet
must be carefully constructed using the proper dimensions
and  it  must  provide  proper  ventilation  to  ensure  proper
appliance operation.
Make  a  separate  kitchen  cabinet
for  each  appliance  for  Side-by-
Side installations.
Consider having a professional install the appliance in your
kitchen cabinet.
4.1 Kitchen Cabinet Airflow
Fig. 4 
- There  must  be  a  ventilation  space  at  least  31  in
2
(200 cm
2
) at the airflow inlet
 Fig. 4 (1)
 and at the airflow
outlet
 Fig. 4 (2)
.
- The top ventilation space can be either directly over the
appliance
 Fig. 4 (2)
 or next to the ceiling over a cabinet
Fig. 4 (3)
, or through a vent installed in a soffit
 Fig. 4 (4)
.
Fig. 5 
- There  must  be  a  clear  ventilation  space  (without  any
obstructions) of at least 1-1/2 in. (38 mm) at the back of
the kitchen cabinet.
u
Observe the above ventilation dimensions.
Ventilation through the cabinet base at the bottom can be
achieved  by  installing  the  provided  ventilation  grille
Fig.  6  (3)
  or  via  a  ventilation  opening  of  at  least  31  in
2
(200  cm
2
).  When  using  the  provided  ventilation  grille
Fig. 6 (3)
, please proceed as follows:
Kitchen Cabinet Construction
4