CONTENTS
Page
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
UNIT INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
LOCATE UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LEVEL UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INSTALL SHELVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CONDENSATE DISPOSAL. . . . . . . . . . . . . . . . . . . . . . . . . . 5
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6,7
PRELIMINARY CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
INITIAL START-UP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
REFRIGERATION SYSTEM SERVICE . . . . . . . . . . . . 8-13
COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SERVICE AND TROUBLESHOOTING . . . . . . . . . . . . . . . 8
MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14,15
LAMP REPLACEMENT  . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CONDENSATE REMOVAL  . . . . . . . . . . . . . . . . . . . . . . . . 14
CONDENSER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CABINET EXTERIOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
INTERIOR SURFACE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
GENERAL
These instructions cover the installation, operation, 
and maintenance of Carrier Miracool™ series glass 
door merchandiser units, sizes 260L, 300L, 750L, 
1100L, and 1300L.
UNIT INSPECTION
Examine all packages for damage to packaging mate-
rial. Damage to external packaging may have resulted 
in unit damage. Check packages for all accessories and 
components, including legs, casters, and shelves. File 
a claim immediately with the shipping company if 
shipment is damaged or incomplete.
INSTALLATION
LOCATE UNIT
Refer to Figure 1 for unit components. Units are 
designed for indoor placement only. Provide at least
3 in. of space between unit cabinet and any adjacent 
wall or fixture. Remove skid base by removing the 
retaining screws (4 hex head bolt screws). If optional 
casters will be used, unit must be located on flat, level 
surface. Refer to Table 1 for a list of standard parts.
 
 TABLE 1 — STANDARD PARTS
NOTE: Parts shown are for standard units. Quantity of shelves and clips may vary based on factory-supplied options.
PART
FACTORY
INSTALLED
FIELD
INSTALLED
UNIT SIZE
260L, 300L
750L
1100L, 1300L
Quantity
Refrigeration Cartridge
X
1
1
1
Shelves
X
4
5
10
Shelf Clips
X
16
20
40
Instruction Manual
1
1
1
Leveling Feet
X
4
4
4
Lamps
X
1
2
2