Hotpoint RB787WC/BC Prospecto

Descargar
Página de 2
Specification Created 7/00
RB787WC/BC - Hotpoint 30" Free-Standing Self-Cleaning Electric Range
Dimensions (in inches)
R
Listed by
Underwriters
Laboratories
All Hotpoint ranges are equipped
with an Anti-Tip device. The 
installation of this device is 
an important, required step in 
the installation of the range.
26-3/8*
46-3/8
1/4
29-7/8
46-1/2
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
The range may be placed with
0" clearance (flush) at the back
wall and side walls if the range
side trims extend beyond the
cabinet fronts at least 1/4".
Self-Clean models only
Note: Check local codes for required breaker size.
A properly grounded branch circuit with a 3 prong grounding type 
receptacle is required for Hotpoint ranges.
Note:  30" Electric Ranges conform to U.L. requirements for 0" spacing
from walls below countertops. However some kitchen cabinet 
finishes can be damaged by heat from the range heating elements. It 
is recommended that a clearance of at least 1-1/2 inches be maintained
to walls. Where varnished wood or plastic film finishes are used, a 
minimum clearance of 6 inches should be maintained.
Receptacle Locations: Locally approved flexible service cord or conduit
must be used because terminals are not accessible after range
installation. See shaded area in drawing for location of electrical outlet
box. Recommended outlet locations allow range to be installed directly
against rear wall.
Installation Information: Before installing, consult installation 
instructions packed with product for current dimensional data. 
KW Rating
240V
10.5
208V
7.9
Breaker Size
40 Amps
*Dimension from wall to front of closed oven door.
Dimension from wall to the front of closed oven 
door handle is 28-1/2.