Hearth & Home Technologies VRT-GR-B-CE Manual De Usuario

Descargar
Página de 44
16
Heat & Glo  •  VRTIKL-CE  •  7031-292 Rev E  •  12/07
90 DEGREE
ELBOW
PIPE LENGTH
PIPE LENGTH
WALL THIMBLE
COVER
WALL THIMBLE
TERMINATION CAP
Step 1. 
Determine the desired location of the gas stove. Check to 
ensure that wall studs or roof rafters are not in the way when 
the flue system is being planned. If this is the case, you may 
want to adjust the location of the gas stove.
E.  Horizontal Termination
Step 3. 
For installations using a round support box/wall thimble 
(check pipe manufacturer's instructions), mark the wall for 
a 25.4 cm x 25.4 cm square hole. The center of the square 
hole should line up with the center line of the horizontal 
pipe, as shown in Figure 5.12. Cut and frame the hole in 
the exterior wall where the flue will be terminated. If the wall 
being penetrated is constructed of noncombustible material, 
i.e. masonry block or concrete, a 17.8 cm diameter hole is 
acceptable.  
CENTER
LINE
CENTER LINE
6 in.
4 in.
Step 2. 
Balanced flue pipe is designed with a locking connection. To 
connect the flue system to the gas stove flue outlet, a twist-
lock adapter is built into the gas stove at the factory.  Wall 
thickness may vary.  Remember to include wall thickness in 
minimum clearances when figuring flueing lengths for your 
installation needs.
Female Locking Lugs
Male Locking Lugs
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use fl ue run supports per installation instructions.
Connect fl ue sections per installation instructions.
•  Maintain all clearances to combustibles.
•  Do NOT allow fl ue to sag below connection 
point to gas stove.
WARNING
Improper support may allow fl ue to sag or separate.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
• Ensure 
fl ue components are locked together correctly.
•  Pipe may separate if not properly joined. 
Step 4. 
Position the horizontal termination cap in the center of the 
25.4cm x 25.4cm square hole and run a bead of non-harden-
ing mastic around its outside edges, to make a seal between 
it and the wall. Attach termination cap to the exterior wall 
with the four wood screws provided. The arrow on the flue 
cap should be pointing up.
Note:  Female ends of balanced flue pipe/elbows are 
designed to slide straight onto the male ends of adjacent 
pipes by orienting the  pipe indentations so they match and 
slide into the  entry slots on the male ends, see Figure 5.13.  
Push the pipe sections completely together, then twist-lock 
one section clockwise approximately one-quarter turn, until 
the two sections are fully locked. The female locking lugs 
may not be visible from the outside. They may be located by 
examining the inside of the female ends.
Figure 5.13 
Figure 5.12