Install Anti-Tip Bracket
1. Remove the anti-tip bracket that is taped in the storage 
drawer.
2. Determine which mounting method to use: floor or wall.
If you have a stone or masonry floor you can use the wall 
mounting method.
3. Determine and mark the edge of the range in the cutout 
space. The mounting bracket can be installed on either the 
left side or right side of the cutout. Position mounting bracket 
in cutout so that right (or left) edge of the bracket is  
⁹⁄₁₆" (14.5 mm) from the marked edge of the range, as shown.
4. Drill two 
¹⁄₈" (3.0 mm) holes that correspond to the bracket 
holes of the determined mounting method. See below.
Floor Mounting  
Wall Mounting
5. Using the Phillips screwdriver, mount anti-tip bracket to the 
wall or floor with the two #12 x 1
⁵⁄₈" screws provided.
Make Gas Connection
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in the following illustration). 
2. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters.
A. Anti-tip bracket
B. Mark edge of range.
C.
⁹⁄₁₆" (14.5 mm)
A. #12 x 1
⁵⁄₈" screws
B. Anti-tip bracket
A
B
C
A
B
A. #12 x 1
⁵⁄₈" screws
B. Anti-tip bracket
A
B
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.