Maytag CPL1100ADH/L/Q/T/W Manual De Usuario

Descargar
Página de 63
Component Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
 
16 
16023522 
©2004 Maytag Services
 
 
Illustration Component 
Test 
Procedure 
Results 
M1 Controlled 
Oven temperature 
adjustment 
Press 
Bake 
pad. 
Enter 
550
 on the digit-pad. 
Immediately press and hold 
Bake
 pad 
for 3 to 5 seconds. 
 
Oven can be adjusted from -35 to +35 
degrees in 5-degree increments by 
pressing 
More + 
or 
Less -
 pads.  To 
avoid over adjusting the oven, move 
temperature 5 degrees each time. 
Wait 4 seconds for the data entry 
timer to expire to accept the change. 
Temperature adjustment is retained 
even through a power failure. 
While increasing or decreasing oven 
temperature, this does not affect self-
cleaning temperature. 
M1 Controlled 
Temperature display 
Press and hold 
Cancel
 and 
Bake
 
pads for 3 to 5 seconds.  Press 
More + 
or 
Less -
 pads to change. 
This mode enables the user to indicate 
°F or °C on the display. 
M1 Controlled 
Clock Display 
Press and hold 
Cancel
 and 
Clock
 
pads for 3 to 5 seconds. 
Allows clock to be toggled On or OFF. 
M1 Controlled 
24 Hour Clock 
Press and hold 
Cancel
 and 
Delay
 
pads for 3 to 5 seconds.  Press 
More + 
or 
Less -
 pads to change. 
Allows the time on the clock to be 
toggled from 12 hour or 24 hour display. 
M1 Controlled 
Factory Default 
Press and hold 
Cancel
 and 
Keep 
Warm
 pads for 3 to 5 seconds until 
beep sounds. 
Allows the clock to be reset to factory 
settings. 
M1 Controlled 
Twelve hour off 
Control will automatically cancel any 
cooking operation and remove all relay 
drives 12 hours after the last pad 
touch. 
See Sabbath mode to disable. 
M1 Controlled 
Sabbath Mode 
Hold 
Clock
 pad for 3 to 5 seconds to 
activate Sabbath mode. 
 
Hold 
Clock 
pad for 3 to 5 seconds to 
disable Sabbath mode. 
 
Desired bake function must be 
initiated before entering Sabbath 
mode. 
"SAb" will be displayed and flash for 5 
seconds then remain on until until timed-
out or cancelled. 
The status “SAB” is NOT fault code 5A6. 
All pad inputs are disabled except for 
CANCEL and CLOCK pads. 
This mode disables the normal 12 hour 
shutoff to allow operation of the bake 
mode for a maximum of 72 hours. 
The oven light is not disabled. 
M1 Controlled 
Child lock out 
Press and hold 
Cancel
 and 
Cook & 
Hold 
pads for 3 to 5 seconds until 
beep sounds.   
To reactivate the control, press and 
hold 
Cancel
 and 
Cook & Hold 
pads
 
for 3 to 5 seconds.  
This is a safety feature that can be used 
to prevent children from accidentally 
programming the oven. It disables the 
electronic oven control. 
 
Child lockout features must be reset after 
a power failure. 
M1 Controlled 
Diagnostic Code 
Display 
Press and hold 
More +
 pad 
within 60 
seconds of powering up the unit.
 
Cycle through the codes using the 
More + 
or 
Less -
 pads. 
The last 5 diagnostic codes will be stored 
in the non-volatile memory. 
 
See "Description of Error Codes" for 
explanation.