Maytag CPL1110ADH/L/T Manual De Usuario

Descargar
Página de 63
Component Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
 
14 
16023522 
©2004 Maytag Services
 
Illustration Component 
Test 
Procedure 
Results 
 
 
Oven light socket 
Test continuity of receptacle terminals ...
Measure voltage at oven light.................
Indicates continuity with bulb inserted. 
120 VAC, see wiring diagram for terminal 
identification. 
If no voltage present, check wiring. 
 
 
 
Rocker switch 
Measure continuity of switch positions: 
Closed.................................................
Open ...................................................
 
Continuity 
Infinite 
 
COM
NO
NC
 
Door lock switch 
Switch connection in following 
positions: Not 
engaged ........................
 Engaged ..............................
Normally Open 
COM-NO=Open, COM-NC=Closed 
COM-NO=Closed, COM-NC=Open 
 
 
Manual Latch 
assembly with switch 
Disconnect wires and test for 
continuity per wiring diagram ..................
 
See wiring diagram for schematic layout. 
Refer to Parts Manual for replacement 
components. 
NOTE: Control will cancel function if 
latch is moved to LOCK position during 
Bake or Broil. 
 
 
Bake burner 
Verify gas is supplied. 
Verify proper orifice installed-Nat or LP ..
Check for obstructions, contamination 
in ports or damage .................................
Air shutter opening:  .469" to .531". 
Blue flame with no yellow tipping. 
 
Replace if punctured or torn. 
 
 
Bake burner 
Models CPL1100AD*, 
CGL1100AD* 
Verify gas is supplied. 
Verify proper orifice installed-Nat or LP ..
Check for obstructions, contamination 
in ports or damage .................................
Air shutter opening:  .349" to .411". 
Blue flame with no yellow tipping. 
 
Replace if punctured or torn. 
 
 
Broil burner 
Verify gas is supplied. 
Verify proper orifice installed-Nat or LP ..
Check for obstructions, contamination 
in ports or damage .................................
Air shutter opening:  .281" to .343". 
Blue flame with no yellow tipping. 
 
Replace if punctured or torn. 
 
 
Ignitor 
Test for voltage at terminals ...................
Test for amount of amperage in circuit ...
(Ignitor may glow, but not have 
sufficient amperage to open valve). 
120 VAC 
3.2 to 3.6 Amps. 
 
 
Temperature sensor 
Measure resistance ................................ Approximately 1000 
Ω at room 
temperature 80
°
F. 
 
 
Gas thermostat 
Models AGR4400AD*, 
CGR1415AD*, 
CGR1110AD*, 
CGL1100AD*, 
CPL1100AD*, 
CP31200AD*, 
CG31200AD*, 
CG31400AD* 
Test for voltage at terminals ................... 120 VAC 
 
 
Gas thermostat 
Model CPR1100AD* 
Test for voltage at terminals ................... 120 VAC 
 
 
Pressure regulator 
Verify gas pressure (WCP).....................
 
If using LP service, verify proper gas 
supply conversion. 
4
"
 Natural 
10
"
 LP/Propane 
 
 
Spark ignition 
electrode 
Test for resistance of spark lead ............
 
Test ignitor to chassis.............................
Continuity 
 
No continuity from ignitor to chassis.