Furuno 2837SW Manual De Usuario
5-1
5. INPUT/OUTPUT DATA
5.1
Radar Processor Unit
Input and output data are shown in the table below.
Input
Data Specifications
Contents
Remarks
synchro or step
GC-10 required
AD-10 format
External AD-100
Heading signal
IEC 61162-2*
AD-10 and
IEC 61162 are
switched by menu
setting.
Alarm ACK input
Contact closure
Input from alarm
system
*: Data input cycle should be more than 40 Hz (HSC) or 20 Hz (normal ship speed).
Output
Radar system data RS-232C
RSD, OSD
For PC plotter
TT data*
IEC 61162-1
TTD, TTM
For ECDIS
Remote display
signal
HD, BP Trigger,
Video
2
ports
Alarm signal
Contact closure
Output to alarm
system by using
photo-relay
4 systems, Output
contents are
selected by menu.
*: The output sentence, mode and baud rate can be set at the TT Preset menu.
IEC 61162 input sentence and priority
Contents
Sentence and priority
Heading (True)
THS*>HDT*
*: THS and HDT are IEC61162-2 sentences.
IEC 61162 output sentence
Contents Sentence
Radar system data
Own ship data
TT target data
Radar system data
Own ship data
TT target data
RSD
OSD
TTD, TLB, TTM
OSD
TTD, TLB, TTM