2. WIRING 
 
2-28
2.9 VDR 
If the distance between VDR and the chart radar is 10 m or less, the VDR can be connected 
directly to the chart radar as follows. 
Processor unit
EC-1000C
Data collecting unit
VR-3010
Radar 
FCR-2107 series
VDR 
VR-3000
D-sub
D-sub
3COX-2P-6C, 10 m
 
 
If the distance between them is more them 10 m, use optional conversion cable and coaxial 
cable(s) as follows. 
D-sub
D-sub
Five coxial cables or
1.5C2V-3C2V-T-20M/30M,
20 m/30 m
BNC
BNC
Conversion cable
BNCX5-DSB15-L700/700 
(40 cm/70 cm)
Processor unit
EC-1000C
Data collecting unit
VR-3010
Radar 
FCR-2107 series
VDR 
VR-3000
 
 
 
2.10  EMI Core for 
Chart Processor Unit 
When connecting the LAN cable MOD-Z072-020+ (supplied) to the chart processor unit 
EC-1000C, attach the EMI core (type: RFC-10, supplied as installation materials) to that 
cable as shown below. 
EC-1000C
RJ45
EMI core
RFC-10
Fasten core with two cable 
ties to fix the core. 
10 cm
MOD-Z072-020+ cable
to LAN Adapter
EC-1010