Furuno FAR-3230SW-BB Manual De Usuario

Descargar
Página de 463
7.  HOW TO MANAGE CHARTS
7-26
unit’s name is moved to the [Grouped with This Unit] window.
To deselect a unit from synchronization: Put a checkmark next to the unit’s 
name in the [Grouped with This Unit] window then click the [>>] button. That unit’s 
name is moved to the [Not Synchronize with This Unit] window.
To deselect all units, click the [Reset All] button.
3. Click the [Save] button to finish.
4. Restart the power on applicable units to apply synchronization configuration 
changes.
7.20.2
How to check synchronization status
You can check chart synchronization status on the [Sync Status] dialog box. Chart 
synchronization operations also are available from this dialog box. Normally, chart 
synchronization is done automatically, according to the sync settings on the [Sync 
Config] dialog box. Use the [Sync Status] dialog box to manually synchronize chart 
data when there is network failure, for example.
Get into the Chart maintenance mode. On the InstantAccess bar, click [System] fol-
lowed by [Sync Status] to show the [Sync Status] dialog box.
[Current Status]: Displays current synchronization status. The table below shows all 
the synchronization status messages.
[Update] button: Click this button to update [Current Status].
[Enable Sync] button: Enables synchronization. The confirmation message "Attention: 
Do you want to enable sync?" appears. Click the [OK] button to enable synchroniza-
tion. Synchronization is always enabled when chart radar starts. A progress bar indi-
cates progress in synchronization. The bar is erased within five minutes after 
completion of synchronization.
[Disable Sync] button: Disables synchronization function temporarily. Use this feature 
to enable chart administration in case of network failure, for example. The confirmation 
message "Attention: Do you want to disable sync?" appears. Click the [OK] button to 
temporarily disable synchronization.
Sync status 
Meaning
[disabled]
Synchronization is disabled.
[must receive]
This chart radar will receive chart data from another FMD-3xx0 or
FAR-3xx0 series.
[must send]
This chart radar will send chart data to another FMD-3xx0 or FAR-
3xx0 series.
[none]
No synchronization task ready.