3.1    Periodic Maintenance Schedule
   
Interval 
Check point 
Check measures 
Remarks 
Weekly 
Display unit 
Periodically clean the exterior of 
display unit using dry soft clean. Use 
of commercially available CRT cleaner 
(spray) having antistatic effect is 
recommended. 
CRT screen produces static charge 
which would attract dust. DO NOT 
use strong solvent like paint thinner 
or abrasive cleaners for cleaning. 
Dust and dirt on CRT creates 
symptoms similar to poor sensitivity. 
Exposed nuts 
and bolts on 
antenna unit 
Check for corroded or loosened nuts 
and bolts, If necessary, clean and 
repaint them thickly. Replace them if 
heavily corroded. 
Sealing compound may be used- 
Instead of paint. Apply a small 
amount of grease between nuts and 
bolts for easy removal in future.   
Antenna radiator
Check for dirt and cracks on radiator 
surface. Thick dirt should be wiped off 
with soft cloth dampened with fresh 
water. If a crack is found, apply a 
slight amount of sealing compound or 
adhesive as a temporary remedy, then 
call for repair.   
Do not use plastic solvent (acetone) 
for cleaning. If you need to remove 
ice from antenna unit, use a wooden 
hammer or plastic. Crack on the unit 
may cause water ingress, causing 
serious damages to internal circuits. 
3 to 6 
months 
Terminal strips 
and plugs in 
antenna unit 
Open antenna cover to check terminal 
strip and plug connections inside. Also 
check the rubber gasket of antenna 
covers for deterioration. 
When closing antenna covers in 
position, be careful not to catch loose 
wires between covers and unit.   
CRT and 
surrounding 
components 
High voltage at CRT and surrounding 
components attract dust in 
environment which will cause poor 
insulation. Ask your nearest FURUNO 
representative or dealer to clean 
internal high-voltage components. 
If CRT anode rubber cap or wire 
sheath is cracked, ask your dealer to 
replace it. Wait for at least 3 minutes 
until high voltage components (CRT 
and HV capacitors) discharge their 
residual charges before accessing 
them. 
6 months 
to one 
year 
Terminal strips, 
sockets, earth 
terminal 
Check for loose connections. Check 
contacts and plugs for proper seating, 
etc. 
 
 
3.2 
Life Expectancy of Major Parts 
Parts   
Type 
Life expectancy 
Remarks 
Antenna motor 
D8G-516 (24 rpm) 
D8G-570 (36 rpm) 
Gear more than 10,000 
hours 
Wind load 100 knots 
Magnetron 
MAF1422B (6kW) 
MAF1425B (10kW) 
9M752/M5187F (25kW) 
2,000-3,000 hours