2-1
2. WIRING 
Wiring consideration 
•  To lessen the chance of picking up electrical interference, avoid where possible routing 
the signal cable near other onboard electrical equipment (radars, transmitting radio 
antennas, etc.) Also avoid running the cable in parallel with power cables. When crossing 
with other cable, the angle should be 90°to minimize the magnetic field coupling. 
•  The signal cable run between the antenna and processor units is available in lengths of 
15 m (standard), 30 m and 50 m. Whatever length is used it must be unbroken; namely, 
no splicing allowed. Use the signal cable as short as possible to minimize attenuation of 
the signal. 
•  The radar should be connected to an emergency power source, as required by SOLAS 
II-1. 
 
2.1 Interconnection 
Processor unit
: Cable requires fabrication
24 VDC or
100-115 VAC/220-230 VAC
Antenna unit
TB801
TB802
Monitor unit
Control unit
(RCU-014 or RCU-015)
Control unit
(RCU-016)
RW-9600
15/30/40/50 m
(Max.100 m)
DPYC-2.5
XH10P-W-5P-A
L=10/20/30m
DPYC-2.5 for AC set
DPYC-6 for DC set
Memory
Card
I/F Unit
CU-200-FAR
XH10P-W-6P L=1.5/10/20/30m*
24 VDC or
100-230 VAC
DVI-D/D SINGLE LINK 5M, 5/10 m
F4
F3
F2
F1
Junction Box
RJB-001*
Junction Box
RJB-001*
*: If the length of the antenna cable is more than 100m, 
    use Junction box RJB-001. However, the maximum length is 300m. 
 
Standard Interconnection