4. Tracked Target (TT) Operation 
 
4-21
4.15 TT 
Alerts 
There are nine situations that cause the TT to trigger visual and audio alarms. To silence the audio alarm, push the 
ALARM ACK key, or select the ALARM ACK box then push the left button. 
TT alerts 
Message no. 
Message 
Alert category
Description 
110 
TT dangerous target 
Alarm 
A TT is on collision course. 
111 
TT target in ACQ ZONE 
Warning 
TT has entered an acquisition zone. The target's 
symbol is red and flashing. 
112 
TT lost target 
Warning 
When the system detects a loss of a TT, a red X is 
superimposed on the target symbol and flashes. 
At the same time, an audible alarm is produced 
for one second. The lost target mark disappears 
from the screen after the lost target alarm is 
acknowledged. 
114 
TT AUTO ACQ 100% full
Warning 
Appears when capacity for automatically acquired 
targets is full. 
115 
TT AUTO ACQ 95% full 
Warning 
Appears when capacity for automatically TTs is 
95% full. 
116 
TT MAN ACQ 100% full 
Warning 
Appears when capacity for manually acquired 
targets is full. 
117 
TT MAN ACQ 95% full 
Warning 
Appears when capacity for manually TTs is 95% 
full. 
118 
TT System error 
Warning 
When the Main CPU receives no signal input 
from TT, the screen shows "TT System error" 
with an indication denoting offending equipment, 
also releasing an audible alarm. 
120 
TT lost REF target 
Warning 
When the system detects a loss of a reference 
target, a red X is superimposed on the target 
symbol and flashes. At the same time, an audible 
alarm is produced for one second. The reference 
target mark disappears from the screen after the 
reference target alarm is acknowledged.