Furuno FCR-2807 Manual De Usuario

Descargar
Página de 540
2. Radar Operation 
 
2-32 
2.22.3  How to restore user settings 
If you get lost in operation while adjusting the settings for a picture setup, you can easily restore user settings for 
that picture setup. Note that user settings are deleted when default settings are restored. 
1.  Left-click the PICTURE box at the left side of the screen to select the picture setup option for which you want 
to restore its user settings.  
2.  Push the right button to show the PICTURE menu. 
3.  Click the User button. 
4.  Click the Close window button (X) to close the PICTURE menu. 
2.22.4  How to restore default picture setup options 
Any of the radar functions programmed with the picture setup options may be adjusted as desired. If you get lost in 
operation and want to restore the default settings for a particular picture setup operation, do the following: 
 
1.  Left-click the PICTURE box at the left side of the screen to select the picture setup option for which you want 
to restore its user settings. 
2.  Push the right button to show the PICTURE menu. 
3.  Click the Factory button. 
4.  Click the Close window button (X) to close the PICTURE menu..  
2.23 Noise 
Rejector 
White noise may show itself on the screen as random "speckles" spread over the entire radar image. You can remove 
this noise as follows: 
1.  Use the trackball to select the PICTURE box at the left side of the screen. 
2.  Push the right button to show the PICTURE menu. 
 
PICTURE menu 
3.  Use the trackball to select the setting of Noise Rej. 
4.  Spin the scrollwheel to select On or Off as appropriate then push the scrollwheel. 
5.  Click the Close window button (X) to close the PICTURE menu.