Furuno FCR-2107-D Manual De Usuario

Descargar
Página de 540
22. Maintenance and Troubleshooting 
 
 
22-7 
22.6 Advanced-Level 
Troubleshooting 
This section describes how to cure hardware and software troubles that should be carried out by qualified service 
personnel.  
Note: This radar equipment contains complex modules in which fault diagnosis and repair down to component level 
are not practicable by users. 
Advanced troubleshooting 
Problem 
Probable causes or 
check points 
Remedy 
Power turned on but radar does 
not operate at all  
1) Blown fuse. 
2) Mains voltage/polarity 
3) Power supply board 
1) Replace blown fuse. 
2) Correct wiring and input voltage.  
3) Replace power supply board. 
Brilliance adjusted but no 
picture 
SPU board 
Replace SPU board. 
Antenna not rotating 
1) Antenna drive mechanism  
2) Defective antenna drive 
motor relay (thermal relay K2, 
200/220/380, 440/100 VAC) 
1) Replace antenna drive mechanism. 
2) Press relay reset button. 
Data and marks not displayed 
in Transmit status 
SPU board 
Replace SPU board. 
Adjust GAIN with A/C SEA 
set at minimum. Marks and 
indications appear but no noise 
or echo 
1) IF amplifier 
2) Signal cable between 
antenna and processor 
unit 
 
 
 
3) Video amplifier board 
1) Replace IF amplifier. 
2) Check continuity and isolation of coaxial 
cable.  
Note: Disconnect the plug and lugs at both 
ends of coaxial cable before checking it by 
ohmmeter. 
 
3) Check video coax line for secure 
connection. If connection is good, replace 
SPU board. 
Marks, indications and noise 
appear but no echo 
(Transmission leak 
representing own ship position 
is absent) 
1) TX high voltage 
protection circuit has activated.
 
2) Magnetron 
 
 
3) Modulator board 
4) SPU board 
1) Reset power to restore normal operation. 
 
 
2) Check magnetron current. 
Replace magnetron.  
 
3) Replace modulator board. 
4) Replace SPU board. 
Picture not updated or picture 
freeze-up 
1) Bearing signal generator 
board (in antenna unit) 
2) SPU board 
3) Video freeze-up 
1) Check the connection of signal cables. 
 
2) Replace SPU board. 
3) Turn off and on the radar. 
Incorrect orientation of picture  1) SPU board 
 
2) Gyro interface 
1) The message GYRO appears when the 
heading pulse is not received during standby. 
2) Replace the gyro interface. 
Cannot operate radar from on-
screen boxes 
SPU Board 
Replace SPU Board.