Furuno FAR-3310 Manual De Usuario

Descargar
Página de 463
24.  MAINTENANCE AND TROUBLESHOOTING
24-3
24.2
How to Replace the Fuses
The fuse in the Power Supply Unit, Processor Unit, monitor unit and sensor adapter
protects those units from overvoltage (overcurrent) and internal fault. If a unit cannot 
be turned on, check if its fuse has blown. If the fuse has blown, find out the cause be-
fore replacing the fuse. If the fuse blows again after replacement, contact your dealer 
for advice.
3 to 6 months
Cabling
Check that all cabling is firmly 
connected and is not dam-
aged.
Exposed bolts and 
nuts of antenna unit
Exposed bolts and nuts are 
subject to corrosion. Further, 
they may loosen by vibration.
Check that bolts and nuts 
are not corroded and are se-
curely fastened. If corroded, 
clean and coat with anticor-
rosive sealant.
Radiator
Dust, dirt and salt deposits on 
the radiator cause signal at-
tenuation, resulting in loss of 
sensitivity. Wipe radiator with 
a freshwater-moistened cloth.
The radiator is made of fiber-
glass reinforced plastic. 
Therefore, do not used gas-
oline, benzene and the like 
to clean the radiator.
If the radiator is iced, use a 
wooden or plastic headed 
hammer to remove the ice. 
DO NOT use a steel ham-
mer.
Terminals, connec-
tors
Check that all terminals and 
connectors on circuit boards 
are securely fastened.
Have a qualified technician 
check terminals and connec-
tors.
6 months to 1 
year
Screws on terminal 
boards in Proces-
sor Units
Check that all screws are 
tightly fastened.
Have a qualified technician 
check screws.
Unit
Power supply
Type
Code no.
Power Supply Unit PSU-014
100-230 VAC
F1: FGBO 250V 7A PBF
000-178-084-10
Power Supply Unit PSU-015
100-230 VAC
F1: FGBO 250V 3A PBF
F2: FGBO 250V 7A PBF
000-155-841-10
000-178-084-10
Power Supply Unit PSU-016
100-230 VAC
F1: FGBO 250V 5A PBF
000-155-840-10
Power Supply Unit PSU-018
100-230 VAC
F1: FGBO 250V 3A PBF
F2: FGBO 250V 7A PBF
000-155-841-10
000-178-084-10
Monitor Unit MU-190
100-230 VAC
FGBO 250V 1A PBF
000-155-828-10
Monitor Unit MU-231
100-230 VAC
FGBO 250V 1.5A PBF
000-155-833-10
Processor Unit EC-3000
100-115 VAC
FGMB 125V 10A PBF
000-157-470-10
220-230 VAC
FGMB 250V 5A PBF
000-157-570-10
Sensor Adapter MC-3000S
24 VDC
FGMB 125V 3A PBF
000-157-481-10
Interval
Check point
Check and measures
Remarks
Use the proper fuse.
Use of a wrong fuse can damage the 
equipment or cause fire.
WARNING