2-5
   2 PREPARATION FOR MEASUREMENT
2.5
Vertical and Horizontal Angle Tilt Correction
(GPT-2009 has vertical angle tilt correction only.)
When the tilt sensors are activated, automatic correction of  vertical and horizontal angle for 
mislevelment is displayed.
To ensure a precise angle measurement, tilt sensors must be turned on.  The display can also be used 
to fine level the instrument.  If the (TILT OVER) display appears the instrument is out of automatic 
compensation range and must be leveled manually.
GPT-2000 compensates both the vertical angle and the horizontal angle readings due to inclination 
of the standing axis in the  X and Y  directions .
For more information about dual axis compensation, refer to APPENDIX 1 “Dual Axis 
Compensation”.
The display of Vertical or Horizontal angle is unstable when instrument is on an unstable stage or  a 
windy day.  You can turn off the auto tilt correction function of V/H angle in this case.
Zenith
Standing axis
Inclination of the standing
axis in the  X direction
Zenith
Inclination of the standing 
axis in the  Y direction
Trunnion axis
Horizontal
Standing axis
V :   °  '  "
HR:   °  '  "
  <X TILT OVER>
V :   °  '  "
HR:   °  '  "
  <Y TILT OVER>
V :   °  '  "
HR:   °  '  "
  <XY TILT OVER>
When the instrument is out of compensation.   (TILT OVER)
Standing Axis in the X direction 
out of range
Standing Axis in the Y direction 
out of range
Standing Axis in the X and Y 
directions out of range