Topcon GPT-2000 Manual De Usuario

Descargar
Página de 168
4-4
   4 DISTANCE MEASUREMENT
Choose meter /feet / feet+inch unit by soft key
It is possible to change the unit for distance measurement mode by soft key.
This setting is not memorized after power off. Refer to 16 “SELECTING MODE” to set at the initial 
setting (memorized after power off).
4.5
Fine Mode/Tracking Mode/Coarse Mode
This setting is not memorized after power is off. Refer to Chapter 16”SELECTING MODE” to set at the 
initial setting (memorized after power is off).
•Fine Mode
: This is a normal distance measuring mode.
The unit to be displayed: 0.2mm or 1mm. (0.001ft or 0.005ft)
Measurement time
0.2mm mode: approx. 3.0 sec.
1mm mode: approx. 1.2 sec.
•Tracking Mode : This mode measures in shorter time than in fine mode.
It is very useful when tailing the moving object or carrying out stake-out work.
The unit to be displayed: 10mm
Measuring time: approx. 0.3 sec.
•Coarse Mode
: This mode measures in shorter time than in fine mode.
The unit to be displayed: 10mm or 1mm
Measuring time: approx. 0.5 sec.
Operating procedure
Operation
Display
1
Press the [F4](P1
) key  twice to get the function 
on page 3.
[F4]
2
Every time pressing the [F2](m/f/i) key, the display 
unit will be changed.
Every time pressing the [F2](m/f/i) key, the unit 
mode switches.
[F2]
Operating procedure
Operation
Display
1
Press the [F2](MODE) key from the distance 
measuring mode.*1)
The initial character (F/T/C) of set mode is 
displayed . (F:Fine, T:Tracking, C:Coarse)
[F2]
2
Press the [F1](FINE) key, [F2](TRACK) key, or 
[F3](COARSE) key.
[F1]~[F3]
*1) To cancel the setting, press the  [ESC] key.
HR: 120°30'40" 
HD*     2.000 m
VD:     3.000 m
MEAS MODE  NP/P  P1
OFSET S.O  S/A   P2
 --- m/f/i ---   P3
HR: 120°30'40" 
HD*     6.560 f
VD:     9.845 f
 --- m/f/i ---   P3
HR: 120°30'40" 
HD*    123.456m
VD:      5.678m
MEAS MODE  NP/P  P1
HR: 120°30'40" 
HD*    123.456m
VD:      5.678m
FINE TRACK COARSE F
HR: 120°30'40" 
HD*    123.456m
VD:      5.678m
MEAS MODE  NP/P  P1