Furuno GP-3300 Manual De Usuario

Descargar
Página de 137
 11-7
2. Select YES from the POS CORR field.
3. Select 
 L/L from the MODE field.
4.  Enter latitude and longitude correction values.
5. Press the [ENT] key.
Cancelling chart position correction
1. Press [MENU] and [6].
2. Select NO from the POS CORR field.
3. Press the [ENT] key.
11.6 Loran TD Correction
When the Loran A or Loran C TD display shows constant error you
can correct it as follows:
1. Press the [MENU] key.
8 INITIAL SETTINGS
AUTOPILOT DISPLAY = ON
OFF
TD INDICATION
= LA
LC
OFF
STATION PAIR
= 00-01
TO CORRECTION 1
= 000.0 
µ
S
TO CORRECTION 2
= 000.0 
µ
S
SELF TEST
:  OK
PROGRAM NO.
:  14517020xx
Figure 11-10 INITIAL SETTINGS menu, lower half
2. Press the [8] key to display the INITIAL SETTINGS menu.
3. Select TD CORRECTION 1.
4. Enter TD correction value in microseconds. If the value is -0.1
microseconds, for example, press [0], [0], [0], and [1].
5. Select TD CORRECTION 2 and enter TD correction value in
microseconds.
6. Press the [ENT] key.