Siemens S120 Manual De Usuario
Technical data and characteristics
14.2 Data sheets and diagrams
14.2.3
1FW6150-xxxxx-xxxx
Data sheet 1FW6150-xxB05-xxxx
Table 14- 9 1FW6150-xxB05-1Jxx, 1FW6150-xxB05-4Fxx
Technical data
1FW6150
1FW6150
Symbol
Unit
-xxB05-1Jxx -xxB05-4Fxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Rated data
Rated torque
M
N
Nm
338
298
Rated current
I
N
A
17
36
Maximum speed at rated torque
n
MAX,MN
rpm
230
650
Rated power dissipation
P
V,N
kW
2.57
2.52
Limit data
Maximum torque
M
MAX
Nm
710
710
Maximum current
I
MAX
A
44
100
Electric power of motor at M
MAX
P
EL,MAX
kW
22.8
39.4
Maximum speed at maximum torque
n
MAX,MMAX
rpm
110
330
No-load speed
n
MAX,0
rpm
350
830
Torque at n = 1 [rpm]
M
0
Nm
360
360
Current at M
0
and n = 1 [rpm]
I
0
A
18
44
Thermal static torque
M
0
*
Nm
255
255
Thermal stall current
I
0
*
A
12
30
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
19.8
8.26
Voltage constant
k
E
V/(1000/min)
1199
499.6
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
7.2
7.26
Thermal time constant
t
TH
s
60
60
No. of pole pairs
p
-
33
33
Cogging torque
M
COG
Nm
1.8
1.8
Stator mass
m
S
kg
17.9
17.9
Rotor mass
m
L
kg
3.8
3.8
Rotor moment of inertia
J
L
10
-2
kgm
2
10.1
10.1
Phase resistance of winding at 20 °C
R
STR, 20
Ω
1.82
0.31
Phase inductance of winding
L
STR
mH
9.4
1.6
Data, main motor cooler
Maximum dissipated thermal power
Q
H,MAX
kW
2.13
2.1
Recommended minimum volume flow rate
H,MIN
l/min
4.5
4.5
1FW6 Built-in torque motors
198
Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3