3.  MAINTENANCE, TROUBLESHOOTING
29
3.4
How to Replace the 
Fuse
The two fuses (Type: FGBO-A 125V 2A PBF, 
Code No.: 000-155-849-10) in the power ca-
ble assy. protect the system from reverse po-
larity of the power supply and equipment fault. 
If you cannot turn on the power, a fuse may 
have blown. FInd the cause before replacing 
the fuse. If the fuse blows after replacement, 
contact your dealer for advice.
3.5
Battery Voltage 
Alert
A battery icon appears at the top of the dis-
play when the battery voltage is too high or 
too low.
Battery icon and meaning
3.6
Troubleshooting
The table below provides basic troubleshoot-
ing procedures which the user may follow to 
restore normal operation.
Troubleshooting table
Icon
Meaning
Voltage is lower than 10 VDC. If the 
voltage goes below 9 V, the equip-
ment is automatically turned off.
Voltage is higher than 32 VDC. If the 
voltage goes higher than 33 V, the 
equipment is automatically turned 
off.
WARNING
Use the proper fuse.
Use of a wrong fuse can result in fire and 
damage the equipment.
If...
then check...
the screen is 
blank
•  adjust the brilliance.
neither echo nor 
fixed range 
scale appears
• battery voltage.
• fuse.
• power cable assy.
no echo ap-
pears but the 
fixed range 
scale appears
•  if display advance 
speed is not set to 
[Stop].
• transducer plug.
• transducer cable.
echo appears 
but zero line 
does not
•  if range shifting is set to 
"0".
•  if zero line rejection is 
“Off”.
•  Check draft setting; it 
should be other than “0”.
sensitivity is low • gain setting.
•  if air bubbles or marine 
life is not clinging to the 
transducer face.
•  if sediments are not 
present in the water.
•  if the bottom is too soft 
to return an echo.
there is extreme 
interference or 
noise
•  if the transducer is too 
close to the engine.
•  if the unit is properly 
grounded.
•  if other echo sounders 
of the same frequency 
as own are being oper-
ated nearby.
the speed/water 
temperature 
readout is unre-
alistic or not 
present
• sensor plug.
the position 
readout is unre-
alistic or not 
present
•  the connection between 
fish finder and naviga-
tor.
• navigator.