Furuno FCV-587 Manual De Usuario
4. INSTALLATION
33
Optional equipment
* WIth ACCU-FISH
TM
, bottom discrimination display support.
4.2
Display Unit
Mounting considerations
The display unit can be installed on a desktop,
or flush mounted in a console. When choos-
ing a location keep the following in mind:
or flush mounted in a console. When choos-
ing a location keep the following in mind:
• Locate the unit away from the air from air
conditioners.
• The operating temperature range is 5°F to
131°F.
• Locate the unit away from devices that emit
active gas.
• The mounting location must be well venti-
lated.
• Select a location where vibration and shock
are minimal.
• Select a location out of direct sunlight. Pro-
longed exposure to direct sunlight can
cause LCD blackout.
cause LCD blackout.
• A magnetic compass will be affected if the
display unit is placed too close to the com-
pass. Observe the compass safe distances
in the safety instructions to prevent distur-
bance to the compass.
pass. Observe the compass safe distances
in the safety instructions to prevent distur-
bance to the compass.
Desktop mounting
1. Remove the tape from the bottom of the
bracket assembly.
Bottom of the bracket
Name
Type
Code No.
Remarks
Transducer
520-5PSD*
000-015-204
Thru-hull mount, plastic
520-5MSD*
000-015-212
Thru-hull mount, metal
525-5PWD*
000-146-966-01
Transom mount, plastic
Triducer (trans-
ducer with speed/
temperature sen-
sor)
ducer with speed/
temperature sen-
sor)
525STID-MSD*
000-011-783
Thru-hull mount, metal
525STID-PWD*
000-011-784
Transom mount, plastic
Converter Cable
Assy.
Assy.
02S4147-1
000-141-082
Speed sensor, Speed/ Temper-
ature sensor
ature sensor
Cable Assy.
KON-004-02M
001-090-910
2 m
Cable Assy.
MJ-A7SPM0001-005+R
000-169-364-10
0.5 m, for Tankenmaru
Speed/ Temper-
ature Sensor
ature Sensor
ST-02MSB
000-137-986-01
Thru-hull type, metal
ST-02PSB
000-137-987-01
Thru-hull type, plastic
Temperature
Sensor
Sensor
T-02MTB
000-040-026
Transom mount, 8 m cable
T-02MSB
000-040-040
Thru-hull type
T-03MSB
000-040-027
Thru-hull type, 8 m cable
Inside Hull Kit S
22S0191-2
000-802-598
w/installation instructions, not
available with bottom discrimina-
tion display.
available with bottom discrimina-
tion display.
Matching Box
MB-1100
000-041-353
For FCV-587, connection to
1 kW transducer
1 kW transducer
Transducer (for
FCV-587)
FCV-587)
50B-6
000-015-042
10 m, 1 kW
50B-6B
000-015-043
15 m, 1 kW
200B-5S
000-015-029
10 m, 1 kW
50/200-1T*
000-015-170
10 m, 1 kW
50/200-12M*
000-015-171
10 m, 1 kW
Tape
(FCV-627 only)