Furuno FCV-587 Manual De Usuario

Descargar
Página de 72
4.  INSTALLATION
37
4. Tape the location shown in the figure be-
low. Fill the gap between the wedge front 
of the transducer and transom with epoxy 
material to eliminate any air spaces.
5. After the epoxy hardens, remove the 
tape.
4.5
How to Mount a 
Thru-hull Trans-
ducer Inside the 
Hull
The thru-hull mount transducer may also be 
installed inside the hull on FRP boats. Howev-
er, this installation method affects the ability to 
detect the bottom, fish and other objects be-
cause the ultrasound pulse is weakened 
when it passes through the hull.
Note: This mounting method should not be 
used to mount the transducer that supports 
the bottom discrimination display feature, 
since performance is greatly degraded.
Necessary tools
You will need the following tools:
Remarks on installation
Installation procedure
If the thickness of the hull varies, then the at-
tenuation of the ultrasound pulse. Select a lo-
cation where attenuation is the lowest.
1. Select 2-3 locations considering the four 
points mentioned below. (You will finalize 
the mounting location through some trial 
and error later.)
•  Mount the transducer at a location 1/2 
to 1/3 of the length of the boat from the 
stern.
•  The mounting location is between 15 to 
50 cm from the centerline of the hull.
•  Do not place the transducer over hull 
struts or ribs which run under the hull.
•  Avoid a location where the rising angle 
of the hull exceeds 15°, to minimize the 
effect of the boat's rolling.
Inside-hull transducer mounting location
2. Clean the face of the transducer to re-
move any foreign material. Lightly rough-
en the face with #100 sandpaper. Also, 
• 
Sandpaper (#100)
• Silicone sealant
• Silicone grease
5x20
5x20
M5x14
5
°
Tape
Bracket
Transducer
Hull
2 to 5
°
Epoxy material
•  Do the installation with the ship moored at a 
dock, etc. The water depth should be 6.5-32 
feet (2-10 meters).
•  Turn off the engine.
• 
Install the transducer with the engine 
room.
•  Do not power the unit with the transducer in 
the air, to prevent damage to the transduc-
er.
•  Do not use this method on a double layer 
hull.
•  Before attaching the transducer to the hull, 
check that the site is suitable. Put the trans-
ducer in a water-filled plastic bag. Connect 
the transducer to the display unit and put 
the transducer on the installation site. Turn 
on the display unit and check that the depth 
indication appears.
1/3
1/2
Centerline
Transducer 
mounting 
location
50 cm
50 cm
15 cm
15 cm