4.  INSTALLATION
43
Thru-hull mount temperature sensor
T-02MSB, T-03MSB
Select a suitable mounting location consider-
ing the following points:
•  Select a mid boat flat position.
•  Select a location where the transducer will 
not be damaged in trailering, launching, 
hauling, and storage.
•  Locate away from equipment which gives 
off heat.
•  Locate away from drain pipes.
•  Select a location where vibration is mini-
mal.
T-02MSB
1. Drill a hole of 21 mm in diameter in the 
mounting location.
2. Pass the sensor cable through the hole.
3. Pass gasket, washer and locknut onto ca-
ble in that order.
4. Coat the sensor flange with high quality 
sealant and then fasten the sensor with 
the locknut. (Torque: max. 59N/m)
5. Launch the boat to check for water leak-
age around the sensor.
How to mount temperature sensor T-02MSB
T-03MSB
1. Drill a hole of 25 mm in diameter in the 
mounting location.
2. Coat holder guide with silicone sealant, 
and pass gasket, washer and locknut 
onto holder guide in that order and then 
tighten the locknut.
3. Set the sensor holder to the holder guide 
from inside the boat. Tighten the locknut.
4. Launch the boat to check for water leak-
age around the sensor.
How to mount temperature sensor T-03MSB
4.9
Wiring
Connect the cable assy. (supplied) to the [12-
24 VDC/NMEA] port, and the transducer ca-
ble to the [XDR] port. Refer to the intercon-
nection diagram to connect cables. Leave 
slack in cables to facilitate checking and 
maintenance. See the next page for how to 
ground the display unit.
Washer
Gasket
φ
21 mm
Coat with 
sealant.
Sensor
cable
Locknut
Holder Guide
Sensor Holder
Locknut
Locknut
Washer
Gasket
φ
25 mm
Coat with 
sealant.
Plate thickness 
within 25 mm