Furuno 1823C Manual De Usuario

Descargar
Página de 100
 
 
 
3-11
3.4 
Checking Magnetron Heater Voltage 
Note: This confirmation/adjustment should only be performed by a qualified service 
technician. 
 
Magnetron heater voltage is formed on the PTU (1833C)/MD (1823C/1933C/1943C/1953C) 
Board of the antenna unit, and preadjusted at the factory. Therefore no adjustment is 
required. However, check magnetron heater voltage for confirmation as follows: 
 
1.  Open the antenna unit. 
2.  Turn on the power. Do not transmit the radar. 
3.  Connect a multimeter, set to 10VDC range, appropriate position on the MD (1823C), 
PTU (1833C) or RTB (1933C/1943C1953C) Board in the antenna unit. Refer to the table 
in below. 
4.  Confirm that the multimeter indication is appropriately. 
 
 
MODEL1823C MODEL1833C 
MODEL1933C/1943C/1953C
Check point 
TP804#6 (+) and #4 (-) 
on MD Board 
TP802#4 (+) and #6 (-) on 
PTU Board 
J825#4 and #6 (GND) on 
RTB Board 
Multimeter indication 
7.9 to 8.1 V 
7.4 to 7.6 V 
7.4 to 7.6 V 
Adjustment point 
VR801 on MD Board 
R106 on PTU Board 
VR801 on MD Board 
 
 
3.5 
Navigation Data Source   
The NAV SOURCE SETTINGS menu mainly selects the source of nav data. For navigator 
other than the FURUNO GP-310B/320B, speed averaging and local time offset (to use local 
time instead of UTC time) are also available from this menu. 
 
1.  Press the [MENU] key followed by SYSTEM CONFIGURATION, NAV OPTION and NAV 
SOURCE SETTINGS soft keys to show the NAV SETUP menu. 
NAV
SETUP
POSITION SOURCE
ALL
SPEED AVERAGING* 
0060second (s)
LOCAL TIME OFFSET*
+00:00
TEMP CALIBRATION
+00  F
DEPTH CALIBRATION
+00ft
* For GPS receiver other than GP-310B/320B.
RETURN
EDIT
 
Nav setup menu